FL Lightning Current / Transient Current Monitor
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
Lightning current monitoring for wind turbine blade down conductors should install applicable FL devices at confirmed blade down-conductor and nacelle acquisition positions, configure FG for aggregation and integrate with SCADA or an O&M platform according to the project interface. Focus on verifying coil aperture, installation orientation, vibration, cable length and nacelle protection conditions; a single lightning-current record must not be taken directly as a blade-damage conclusion.
This solution forms continuous records of wind-turbine lightning events, providing a time basis for blade, SPD and grounding verification. The product combination and installation location must comply with the turbine model structure and on-site maintenance process.
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.
Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.
Used to collect telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are to be confirmed by the FS model.
Configure an applicable FL monitoring device at the blade down conductor or a confirmed lightning-current path.
FG aggregates events at the nacelle or tower-base side and uploads according to the on-site network scheme.
FEXLINK stores turbine-corresponding events, device states and O&M records.
O&M personnel arrange blade, SPD and grounding verification in combination with the event time and wind-turbine inspection procedures.
Turbine Lightning Strike Event Record Count
FL lightning current sensor, recording events where peak reaches the device action threshold
Statistics by turbine ID and time window, cross-referenced with meteorological thunderstorm days and O&M inspection records
Lightning current events alone cannot prove blade structural damage or integrity
Only events within FL model range that triggered recording are counted; does not represent all lightning strikes
No. Event records are used to prompt verification; the blade state still needs to be judged according to the turbine inspection procedures.
No. It can run independently through the platform; SCADA integration is a project integration option.
No. It should be confirmed for each turbine model, based on the blade down-conductor structure, sensor size and maintenance conditions.
FL: records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project; FS: collects telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are confirmed by the FS model.
Select the sensor structure and installation accessories according to the blade down-conductor size and nacelle space; select FL and FG models according to turbine communication, power supply and platform interface; when multi-channel monitoring is needed, confirm the channel definition and installation location according to the turbine model structure.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.
Contact FEXLINK