Home / Solutions / Lightning Protection for Expressway ETC Gantries and Field Equipment

Lightning Protection for Expressway ETC Gantries and Field Equipment

Lightning protection for expressway ETC gantries and field equipment should separately handle power protection, signal protection, grounding and state acquisition. ZL1, ZL2 and ZL5 assume protection responsibilities; ESI can acquire device states that have dry contacts; FS, FSS, FL, FRP, etc., are extended according to on-site needs. Gantry poles, cameras, information boards and backhaul conditions must be confirmed point by point.

Lightning Protection & GroundingLightning Protection Monitoring

Solution overview

This solution addresses the difficulty of localizing field equipment after a lightning strike, first establishing a power and signal protection inventory, then aggregating states that have digital or dry-contact outputs. A protector is not automatically equivalent to a monitor.

Applicable industries

  • Expressways

Primary user roles

  • Mechanical and Electrical O&M
  • Traffic Informatization Engineer
  • Project Integrator

Problems addressed

  • After a gantry, camera or information board is struck by lightning, power-side and signal-side information is insufficient, resulting in a large troubleshooting scope.
  • Interfaces and installation locations differ among field equipment, so a unified configuration requires point-by-point verification.

Recommended product combination

ESI

ESI Digital Status Monitor

Acquires dry-contact states of third-party devices or SPDs; contact voltage, isolation and channel count are confirmed by the model.

System architecture and data flow

Lightning Protection for Expressway ETC Gantries and Field Equipment System TopologyFour-layer data flow across perception, edge control, platform and application for Lightning Protection for Expressway ETC Gantries and Field Equipment.01Perception layer
Configure applicable ZL protectors at field power distribution and signal entrances, and connect FS, FSS or…
02Edge / control layer
CW, FG or confirmed field aggregation devices organize states and upload them.
03Platform layer
The platform displays states and events by gantry, device and protection tier.
04Application layer
Mechanical and electrical O&M arranges on-site verification by gantry and device type after an alarm.

Perception layer

Configure applicable ZL protectors at field power distribution and signal entrances, and connect FS, FSS or ESI state acquisition as needed.

Edge / control layer

CW, FG or confirmed field aggregation devices organize states and upload them.

Platform layer

The platform displays states and events by gantry, device and protection tier.

Application layer

Mechanical and electrical O&M arranges on-site verification by gantry and device type after an alarm.

Data flow

  1. A field power or signal protection device produces a state change.
  2. A device with telemetry signals or dry contacts outputs its state.
  3. Field aggregation devices complete acquisition and upload.
  4. The platform forms gantry-level alarms and O&M records.

Integration and interfaces

  • Confirm whether the ZL model has connectable telemetry signals or dry contacts.
  • Confirm the interface responsibilities of cameras, information boards and communication devices.
  • Pole installation, power supply and backhaul method are confirmed point by point according to field conditions.

Applicable standards

  • JTG technical standards related to highway mechanical and electrical engineering (final version and applicable chapters to be confirmed by the project)
  • GB 50057 Design Code for Lightning Protection of Buildings (applicable clauses to be confirmed by the design documents of facilities along the route)

Acceptance and delivery boundaries

Suggested acceptance dimensions

  • Protectors, acquisition devices and field equipment have a clear correspondence.
  • Protectors without monitorable interfaces are clearly marked in the inventory as protection-only, not monitored.
  • Alarm, offline and recovery states can be distinguished.

Limitations and exclusions

  • ZL protectors do not automatically have full online monitoring capability.
  • Without a signal output, the platform cannot infer that a protector has operated.
  • Pole work must meet traffic, power-supply and working-at-height requirements.

Operational value

  • Reduces the troubleshooting scope after a field-equipment fault.
  • Unifies power and signal protection maintenance inventories.
  • Supports batch state management by gantry.

Selection guidance

  • First confirm the power and signal protection objects, then select ZL1, ZL2 or ZL5.
  • Only when dry contacts or digital interfaces are available should state acquisition such as ESI be evaluated.
  • Gantry grounding and lightning-current monitoring are decided according to on-site paths and product conditions.

Typical implementation patterns

  • A typical implementation pattern is to select one gantry to complete verification of power, signal and protection states.
  • Another pattern establishes a standard configuration by field-equipment type, then adjusts by point.

Before retrofit → With the solution

Before retrofit

  • After a gantry, camera or information board is struck by lightning, power-side and signal-side information is insufficient, resulting in a large troubleshooting scope.
  • Interfaces and installation locations differ among field equipment, so a unified configuration requires point-by-point verification.

With the solution

  • Reduces the troubleshooting scope after a field-equipment fault.
  • Unifies power and signal protection maintenance inventories.
  • Supports batch state management by gantry.

How to evaluate the effect

01

Measurable signal

Configure applicable ZL protectors at field power distribution and signal entrances, and…

02

Data source

ZL1 Type 2 Surge Protective Device (Class II SPD) · ZL2 Type 2 Plug-in Surge Protective Device

03

Review method

Protectors, acquisition devices and field equipment have a clear correspondence.

04

Acceptance boundary

ZL protectors do not automatically have full online monitoring capability.

Frequently asked questions

Can ZL5 definitely upload states?

Cannot be assumed by default. Only specific models with confirmed telemetry signals or dry contacts can be connected.

Are all camera faults caused by lightning?

No. Judgment requires combining power, signal, device logs and on-site inspection.

Is it possible to monitor only the power SPD?

You can pilot the power side first, but signal protection and grounding boundaries still need to be recorded separately.

What devices does "lightning protection for expressway ETC gantries and field equipment" typically consist of?

ZL1: as a power surge protector, assumes T1-class protection responsibility; only specific models with telemetry signals can be connected for state acquisition; ZL2: as a power surge protector, assumes T2-class protection responsibility; cannot replace an independent SPD condition-monitoring terminal; ZL5: as a power surge protection and backup protection product, specific protection parameters, telemetry signals and model lineup are confirmed by the datasheet; ESI: acquires dry-contact states of third-party devices or SPDs, with contact voltage, isolation and channel count confirmed by the model.

What site conditions should be verified before implementing "lightning protection for expressway ETC gantries and field equipment"?

First confirm the power and signal protection objects, then select ZL1, ZL2 or ZL5; only when dry contacts or digital interfaces are available should state acquisition such as ESI be evaluated; gantry grounding and lightning-current monitoring are decided according to on-site paths and product conditions.

Request a matched product combination and project review

Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.

Contact FEXLINK