FL Lightning Current / Transient Current Monitor
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
Lightning monitoring for primeval forests and areas without mains power should first clarify the monitoring substrate, power-supply capability, weak-network strategy and inspection cycle, then select FL or FL-11122 together with FG and the platform. Solar panels, batteries and protective enclosures are engineering accessories and must be designed according to on-site conditions; without reliable energy and a mounting substrate, continuous online operation must not be promised.
This solution is for retaining lightning events in remote areas, focusing on low maintenance and data integrity during network disconnection. The solution does not default to having all environmental monitoring capabilities; the product combination centers on lightning-current event recording.
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.
Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.
Used for 0.1 kA to 1 kA transient current event recording; must not be confused with the range of main lightning-current products.
Install FL or FL-11122 at a confirmed down conductor or conductor path, and configure applicable outdoor protection and power-supply conditions.
FG aggregates locally and retains caching; the backhaul strategy is set according to network conditions.
FEXLINK receives the data that can be backhauled and marks the time, device and communication state.
Inspection personnel check power supply, storage and device state periodically, and export the required event records.
Install FL or FL-11122 at a confirmed down conductor or conductor path, and configure ap…
FL Lightning Current / Transient Current Monitor · FG Smart Gateway (Zigbee, RS485 & Ethernet)
The monitoring point establishes a unique correspondence with the target conductor and facility.
This solution does not default to having meteorological, flash-flood, seismic or slope-displacement monitoring capabilities.
It can be realized through engineering accessory power supply, but the endurance depends on device power consumption, sunlight and maintenance conditions, requiring a special calculation.
Local storage can be used according to device capability; the backhaul and export methods need to be confirmed in the solution.
Outdoor power supply, protection and communication are all affected by the environment, so periodic inspection is still required.
FL: records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project; FL-11122: used for 0.1 kA to 1 kA transient current event recording, and must not be confused with the range of main lightning-current products.
For direct-lightning paths select an applicable FL; for small-current transients evaluate FL-11122; design the energy system according to sunlight, maintenance cycle and power-supply budget; network conditions determine real-time backhaul, scheduled backhaul or on-site export.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.