FL Lightning Current / Transient Current Monitor
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
Direct lightning current event recording should, under the condition of clarified down-conductor path, conductor size and installation orientation, adopt an applicable FL lightning-current recording device and aggregate via FG. The page may describe event time, path and recording purpose, but peak range, waveform capability, protection rating and installation method must be confirmed by the specific model and datasheet.
This solution reduces the problem of lacking event evidence after a lightning strike. The starting point of data value is correctly selecting the monitored conductor and installation location, rather than inferring the lightning path from alarms alone after the fact.
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.
Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.
Install an applicable FL recording device on a confirmed down conductor or lightning-current path.
FG aggregates lightning-current events and associates them with station, line or facility codes.
FEXLINK stores event time, device state and O&M verification records.
Lightning-protection and O&M personnel check SPDs, grounding and site facilities according to the event time.
Install an applicable FL recording device on a confirmed down conductor or lightning-cur…
FL Lightning Current / Transient Current Monitor · FG Smart Gateway (Zigbee, RS485 & Ethernet)
The monitoring point establishes a unique correspondence with the protected object, down conductor or facility.
Lightning-current recording alone cannot prove that the protected equipment is definitely damaged or undamaged.
A conductor that can represent the target lightning-current path and meets the sensor installation conditions should be selected, and confirmed on site by a lightning-protection professional.
The system should not be shut down directly based on event records alone; judgment should be made according to the project contingency plan in combination with SPD, grounding and equipment states.
Coverage cannot be assumed by default. The coverage scope is related to the installation location, conductor path and specific product capability, and requires point-by-point design.
FL: records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project.
Select the sensor structure and installation accessories according to the size and orientation of the down conductor or conductor; select the specific FL model according to indoor/outdoor environment, communication method and maintainability; when small-current transient monitoring is needed, evaluate FL-11122 rather than directly extending the range of the main lightning-current device downward.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.