Oil Tank Grounding Resistance Monitoring Solution
0.01Ω Resolution · 200Ω Range · 7×24h Online
FR Three-Pole Method + FRP Clamp Method Dual-Mode Measurement, Ex ia IIC T4 Explosion-Proof Meets Petrochemical Scenarios, FG Gateway Unified Aggregation Cloud Upload, O&M Cost Reduction 80%
The Oil Tank Grounding Resistance Monitoring Solution is an online monitoring system developed by FEXLINK to oil tank farms. The system monitors grounding resistance, lightning current, and SPD status in Real-Time, replacing traditional manual measurement, ensuring lightning protection safety in tank farms.
Solution Architecture
Architecture
Core Functions
Core Functions
Three-Pole Method/Clamp Method Dual-Mode
FR Fall-of-Potential Method Precision Measurement, FRP Clamp Method No Auxiliary Electrode Fast Inspection
High Precision Wide Range
0.01Ω~200Ω Measurement Range, <5% Measurement Error
Multi-Point Synchronous Monitoring
Same Grid Network Multiple Monitoring Monitor Synchronous Acquisition MoM Analysis
Trend Change Smart Analysis
Auto Analysis of Seasonal/Weather Change Pattern, Scientific Assessment Grounding Status
Over-Limit Tiered Alarm
Multi-Level Threshold Configurable, Over-Limit Auto Alarm Push to Responsible Person
Lightning Event Record
Gateway Associated Lightning Current Monitoring Data, Record Lightning Strike Time & Resistance Value Change
Customer Cases
Case Studies
Substation Grounding Grid
SubstationInspection Frequency from Monthly Reduced to On-Demand Need, O&M Cost Reduction 80%
Petrochemical Tank Farm Explosion-Proof Area
PetrochemicalGrounding Fault Response Time Reduction 90%, Ex ia IIC T4 Safety Certification
Key Points
- Definition: The Oil Tank Grounding Resistance Monitoring Solution is FEXLINK's online monitoring solution for outdoor grounding systems at oil tank farms and substations, using FR/FRP-series ground resistance monitors for 24/7 continuous monitoring.
- Core Capabilities: Based on the three-electrode (fall-of-potential) method; supports multi-point synchronous acquisition, trend analysis and threshold alarms with 0.01Ω resolution, strong interference immunity for harsh outdoor environments, and RS485 data upload.
- Scenarios: Suitable for outdoor grounding system monitoring at oil tank farms, substations, telecom base stations, lightning rod grounding grids and towers.
- Related Products: FR Three-Point Ground Resistance Monitor, Indoor Ground Resistance Monitor, FG Smart Gateway, FEXLINK Cloud grounding monitoring solution.
Frequently Asked Questions
Solution FAQ
What is Oil Tank Grounding Resistance Monitoring Solution?
The Oil Tank Grounding Resistance Monitoring Solution is FEXLINK's online monitoring solution for outdoor grounding systems at oil tank farms and substations, using FR/FRP-series ground resistance monitors for 24/7 continuous monitoring.
What problems does Oil Tank Grounding Resistance Monitoring Solution solve?
Solves the limitations of manual periodic megger testing — high on-site labor cost, long measurement intervals, no Real-Time data upload, and delayed anomaly alarms.
What scenarios does Oil Tank Grounding Resistance Monitoring Solution apply to?
Suitable for outdoor grounding system monitoring at oil tank farms, substations, telecom base stations, lightning rod grounding grids and towers.
What are the core advantages of Oil Tank Grounding Resistance Monitoring Solution?
24/7 online monitoring, 0.01Ω high resolution, no on-site personnel required, Real-Time data upload with threshold alarms — supporting safe and compliant operation of oil tank farm grounding systems.
How can I contact FEXLINK or request a demo?
Submit requirements via the Contact page on the FEXLINK website, or call +86-755-8653-6148 to request a demo and solution consultation; engineers will propose a matched solution and quotation based on your scenario.
Safeguard Grounding System Safety
Contact UsFEXLINK Business Scope
FEXLINK 微物联,专注配电场景电气安全与数字能源技术研发。我们以多维精准感知与智能算法为核心,通过端侧感知芯片、多维电气时序特征算法、三层电碳大模型,实现雷电防护、接地监测、电气隐患识别;同步完成配电计量、电能质量分析、回路级碳排核算。面向老旧柜体与工业配电,构建从现场采集、本地芯片推理到云端电碳智能中枢的端云协同体系,赋能能源安全管控、能效优化与低碳数字化落地。