The ZLS2 Type 1 SPD is a Class I high-energy SPD with ZLS2 series specifications, providing direct Lightning Strike protection for main distribution boards. It is engineered for high-energy lightning environments requiring robust first-stage protection.

50kA
Max Impulse Current Iimp
≤100ns
Response Time
2.5kV
Voltage Protection Level Up
T1 Class Protection Spark Gap Technology Direct Lightning Energy Discharge Intrinsically Safe No Fire Modular Plug-In Ultra-Compact Body
Product Overview

Product Overview

ZL(S)2SPD(T1) adopts spark gap technology, specifically born for discharging high-energy direct lightning. Transcends ordinary metal oxide varistor, can withstand maximum 50kA (10/350us) extreme high impulse current (Iimp), is the ideal choice for power incoming ends (LPZ0-1) protection.

After discharge, effectively cuts off power-frequency follow current, fundamentally avoiding Thermal Runaway and Fire Risk caused by SPD degradation short-circuit.72mm ultra-compact body integrates T1 class Full Protection Circuit,Compliant with GB 18802.11,IEC 61643-11 Standard.

Core Capabilities

  • Powerful Direct Lightning Capacity: Energy Dissipation Capacity and Thermal Capacity Far Exceeds Ordinary Through Varistor Resistance, Can Withstand Up to 50kA (10/350us Waveform) Impulse Current.
  • Intrinsically Safe, No Fire Risk: After discharge, effectively cuts off power-frequency follow current, avoids thermal runaway and fire caused by SPD degradation short-circuit.
  • Modular Plug-in Design: Module and Socket Separation, Protection Module Can Be Separately Thermally Replaced After Failure, No Need to Stop Electrical or Disassemble Wiring.
  • High-Performance Density Design: 72mm Ultra-Compact Body Integrates T1 Class Full Protection Circuit, Small Size Large Performance.
Product Features

Product Features

Strong Direct Lightning Withstand Capability

Energy dissipation capacity and thermal capacity far exceed ordinary metal oxide varistor (MOV), can withstand up to 50kA impulse current (10/350us waveform, Iimp), perfectly meeting T1 class protection strict requirements for direct lightning strike partial-point energy discharge.

Intrinsically Safe, No Fire Risk

After Discharge, Effectively Cuts Off Power-Frequency Follow Current,Fundamentally Avoids Due to SPD degradation Short-Circuit Causing Thermal Runaway and Fire Risk,Protects Power Distribution System Secure Operation.

Modular Plug-in Design

Acquisition Uses Module and Socket Separation Design, Protection Module Can Be Separately Thermally Replaced After Failure, No Need to Stop Electrical or Disassemble Wiring, Reducing Maintenance Cost and Time.

High-Performance Density Design

In ultra-compact 72mm width, integrates T1 class full protection circuit. 275V, 2.5kV Up value, small size with large performance, and micro-type break channel device dimension phase imitation.

Long Lifespan, Slow degradation

Petrochemical-grade material resists electrical arc and impulse, performance parameters remain stable after multi-order actions, with lifespan and reliability higher than conventional devices, protection cost lower.

Fast Response, Low Residual voltage

Response time ≤100ns, can act fast at the early uprising stage of overvoltage wave. Voltage Protection Level (Up) as low as 2.5kV, providing fine protection for UPS, servers, PLC and other devices.

Selection Guide

Model Selection Guide

Model Naming Convention

ZLx - structure - Iimp / Uc - protection mode
ZLx
Product Category
1:T1 Power Supply SPD;S1:T1 Power Supply SPD(Dry Contact);2:T2 Power Supply SPD;S2:T2 Power Supply SPD(Dry Contact);3:T3 SPD;4:Signal No. SPD
structure
Core Structure
V:Varistor;F:Discharge Tube;G:Spark Gap;BC:Composite Type
Iimp
Max Impulse Current
6kA(6.25kA);12kA(12.5kA);15kA;25kA;40kA;50kA
Uc
Max Continuous Running Voltage
AC:255/275/320/385/440/690/760V;DC:500/600/800/1000/1200/1500/1800/2000V
mode
protection mode
AC:1P;2P;3P;4P;1+NPE;3+NPE;DC:U;Y
Imax
Max Discharge Current
20kA;40kA;60kA;80kA;100kA
Model structure Pole Count Uc Iimp Up Response Time dimension(long×wide×highmm) localindicator Dry Contact
ZL1-G-12.5/275-4PSpark Gap4P275V12.5kA2.5kV≤100ns72×83×67---
ZLS1-G-15/385-4PSpark Gap4P385V15kA2.5kV≤100ns72×83×67
ZL1-G-25/320-3+NPESpark Gap3+NPE320V25kA2.5kV≤100ns72×90×71---
ZLS1-G-25/275-1+NPESpark Gap1+NPE275V25kA2.5kV≤100ns36×90×71
ZL1-G-40/385-4PSpark Gap4P385V40kA2.5kV≤100ns144×91×65---
ZL1-G-50/690-3+NPESpark Gap3+NPE690V50kA2.5kV≤100ns144×91×65---
Technical Parameters

Technical Specifications

Basic Parameters

Working VoltageAC 220V
Mounting MethodStandard 35mm DIN Rail Mount
Operating Temperature-40℃~70℃
Working Humidity5%~95%
Housing MaterialThermalplastic flame-retardant materialPBT G20 V0
Protection ClassIP20
Execute StandardGB 18802.11,IEC 61643-11

Surge Protection Parameters

Protection ClassT1
CorestructureSpark Gap(G)
Max Continuous Running Voltage Uc275V/320V/385V/690V/760V AC
Max Impulse Current Iimp12.5kA/15kA/25kA/40kA/50kA
Voltage Protection Level Up2.5kV
Response Time≤100ns
4P Dimensions72×83×67 / 144×91×65 mm
3+NPE Dimensions72×90×71 / 144×91×65 mm
1+NPE Dimensions36×90×71 mm
Installation Instructions

installation Instructions

a

Installation Dimensions Image

ZL(S)2SPD(T1) Installation Dimensions Image
ZL(S)2SPD(T1) Installation Dimension Image
b

Interface Description

Power Supply Interface Definition

NumberInterfaceDefinition
1L1,L2,L3three-phaselive wire
2NNeutral Wire
3PEground wire

Key Points

  • Definition: The ZLS2-T1 Class I SPD is FEXLINK's T1 SPD designed for Class I protection at the Power Incoming end, with high direct-lightning current handling.
  • Core Capabilities: Voltage-switching structure with high Imax, suitable for main Power Incoming direct-lightning protection, can coordinate with T2 SPDs.
  • Scenarios: Suitable for Class I lightning protection in main distribution of critical buildings, industrial plant incoming lines, and outdoor facilities.
  • Related Products: T1 Class I SPD, T2 Class II SPD, FSS Smart SPD.

Frequently Asked Questions

Product FAQ

What is ZLS2-T1 Class I SPD?

The ZLS2-T1 Class I SPD is FEXLINK's T1 SPD designed for Class I protection at the Power Incoming end, with high direct-lightning current handling.

What scenarios does ZLS2-T1 Class I SPD apply to?

Suitable for Class I lightning protection in main distribution of critical buildings, industrial plant incoming lines, and outdoor facilities.

How does ZLS2-T1 Class I SPD differ from traditional solutions?

Compared with T2 SPDs, the ZLS2-T1 is dedicated to Class I direct-lightning protection, with higher current handling and a 10/350μs waveform.

How is ZLS2-T1 Class I SPD installed and integrated?

Install on the main Power Incoming side per L/N/PE codes, with a dedicated backup-protection device upstream.

How can I purchase FEXLINK products or request a demo?

Submit requirements via the Contact page on the FEXLINK website, or call +86-755-8653-6148 to request a demo and selection consultation; engineers will propose a matched solution and quotation based on your scenario.

FEXLINK Business Scope

FEXLINK specializes in smart lightning protection and electrical safety, offering a product portfolio covering lightning protection, lightning online monitoring, lightning protection online monitoring, lightning arrester, intelligent lightning arrester, lightning arrester monitoring, grounding resistance, grounding monitoring for smart lightning protection scenarios, while addressing digital distribution, smart distribution, electricity meter, carbon neutral, industrial internet, carbon asset for digital business, helping enterprises achieve safe, efficient and low-carbon energy management.