Home / Solutions / Induced Lightning and Transient Current Monitoring

Induced Lightning and Transient Current Monitoring

Induced lightning and transient current monitoring should clarify whether small-current events on the distribution incoming line, signal line or equipment branch are to be observed, and select models such as FL-11122 that cover the corresponding range. This solution supplements event localization information and cannot replace main lightning-current recording, SPD degradation assessment or EMC rectification.

Lightning Protection & GroundingStatus Visualization

Solution overview

This solution is for observing small-current transient events with a clarified range. Before implementation, different phenomena such as direct lightning, induced lightning and equipment-switching overvoltage must be distinguished, to avoid interpreting data from one channel as a complete source determination.

Applicable industries

  • Industrial and Public Infrastructure

Primary user roles

  • Lightning Protection Engineer
  • Electrical Operations and Maintenance
  • Project Integrator

Problems addressed

  • When transient disturbances occur on the distribution incoming line, there is a lack of relatable time and path information.
  • Sensors for different current ranges are easily mixed, causing data that cannot be interpreted on the same basis.

Recommended product combination

FEXLINK

FEXLINK IoT Platform

Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.

System architecture and data flow

Induced Lightning and Transient Current Monitoring System TopologyFour-layer data flow across perception, edge control, platform and application for Induced Lightning and Transient Current Monitoring.01Perception layer
Install FL-11122 or an applicable transient current monitoring device at a confirmed conductor location.
02Edge / control layer
FG aggregates events and retains the measurement point, direction and device state.
03Platform layer
FEXLINK displays event records and supports correlated viewing with SPD and device alarms.
04Application layer
O&M personnel verify the records in combination with power distribution operations, weather and equipment ev…

Perception layer

Install FL-11122 or an applicable transient current monitoring device at a confirmed conductor location.

Edge / control layer

FG aggregates events and retains the measurement point, direction and device state.

Platform layer

FEXLINK displays event records and supports correlated viewing with SPD and device alarms.

Application layer

O&M personnel verify the records in combination with power distribution operations, weather and equipment events.

Data flow

  1. A transient current change occurs on the monitored conductor.
  2. FL-11122 records events within the model-supported range.
  3. FG aggregates events and uploads them to the platform.
  4. The platform retains events and supports subsequent correlated troubleshooting.

Integration and interfaces

  • Confirm that the conductor can be clamped, the sensor fixing orientation and the available installation space.
  • Clarify the circuit corresponding to the measurement point, avoiding mixing line names and device names.
  • When integrating with the platform, retain time synchronization, event number and communication state.

Applicable standards

  • IEC 62305 series standards for protection against lightning (applicable parts and version to be confirmed by the project)
  • GB 50057 Design Code for Lightning Protection of Buildings (applicable clauses and version to be confirmed by the project location and design documents)

Acceptance and delivery boundaries

Suggested acceptance dimensions

  • The measurement point establishes a correspondence with a specific circuit or device.
  • Event records can be distinguished from states such as device offline and communication interruption.
  • After installation, conductor insulation, fixing and protection conditions meet site requirements.

Limitations and exclusions

  • FL-11122 cannot be used to replace full-range main lightning-current recording.
  • A single transient event cannot directly prove the source of a lightning strike or the cause of equipment damage.
  • Without confirmed conductor and installation conditions, live-line work must not proceed.

Operational value

  • Provides time records and troubleshooting clues for transient events.
  • Helps distinguish incoming-line disturbances from individual equipment faults.
  • Supplements on-site event information beyond SPD state.

Selection guidance

  • First confirm whether the event to be monitored is in the 0.1 kA to 1 kA range.
  • Select the specific model according to conductor size, installation method and communication suffix.
  • When direct-lightning main-path recording is needed, select an applicable main lightning-current FL model.

Typical implementation patterns

  • A typical implementation pattern is to set one representative measurement point on a key incoming circuit first, then expand to circuits with frequent anomalies.
  • Another pattern is to jointly verify transient events with SPD alarms and equipment operation logs.

Before retrofit → With the solution

Before retrofit

  • When transient disturbances occur on the distribution incoming line, there is a lack of relatable time and path information.
  • Sensors for different current ranges are easily mixed, causing data that cannot be interpreted on the same basis.

With the solution

  • Provides time records and troubleshooting clues for transient events.
  • Helps distinguish incoming-line disturbances from individual equipment faults.
  • Supplements on-site event information beyond SPD state.

How to evaluate the effect

01

Measurable signal

Install FL-11122 or an applicable transient current monitoring device at a confirmed con…

02

Data source

FL-11122 Transient Current Monitor (Indoor) · FG Smart Gateway (Zigbee, RS485 & Ethernet)

03

Review method

The measurement point establishes a correspondence with a specific circuit or device.

04

Acceptance boundary

FL-11122 cannot be used to replace full-range main lightning-current recording.

Frequently asked questions

Can this solution measure direct lightning current?

FL-11122 must not be used as a main lightning-current device. Its published range is for small-current transient recording; for direct lightning, an applicable model should be selected separately.

Does a high number of transient events indicate lightning-protection failure?

A conclusion cannot be drawn directly. It also needs to be judged comprehensively in combination with SPD state, grounding, equipment operation and on-site inspection.

Can a sensor be shared across multiple circuits?

Sharing cannot be assumed by default. The conductor, orientation and installation conditions of each circuit need to be verified individually.

What devices does "induced lightning and transient current monitoring" typically consist of?

FL-11122: used for 0.1 kA to 1 kA transient current event recording; must not be confused with the range of main lightning-current products; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project.

What site conditions should be verified before implementing "induced lightning and transient current monitoring"?

First confirm whether the event to be monitored is in the 0.1 kA to 1 kA range; select the specific model according to conductor size, installation method and communication suffix; when direct-lightning main-path recording is needed, select an applicable main lightning-current FL model.

Request a matched product combination and project review

Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.