Pluggable Multi-Pulse Surge Protective Device
Smart Lightning Protection

Pluggable Multi-Pulse Surge Protective Device

Pluggable multi-pulse SPD with built-in backup protection: multi-pulse peak current 40kA, 10-pulse capability, response ≤25ns and 100A power-frequency short-circuit breaking. Supplied in 2P, 3P and 4P versions for 230V and 400V systems.

40kA
Multi-pulse peak
≤25ns
Response time
100A
Built-in backup

Overview

Pluggable Multi-Pulse Surge Protective Device · Product
Distribution boards in high-thunderstorm areas
PV and energy-storage DC-side protection
Power entry of communication base stations

Key Features

Multi-pulse withstand

10P multi-pulse capability for repeated lightning strikes in thunderstorm-prone areas.

Built-in backup protection

Integrated power-frequency short-circuit protector, Isc 100A, breaking time 0.9~1.5s.

Nanosecond response

Response time ≤25ns with a voltage protection level Up ≤1500V.

Pluggable modules

Replaceable plug-in cartridges shorten replacement time and maintenance downtime.

Three protection modes

L/N-PE, three-phase without N, and three-phase with N-PE.

DIN rail mounting

Standard 35mm DIN rail, pluggable module, IP20.

Technical Data

Operating voltage Un230V / 400V
Multi-pulse peak current IM40kA
Multi-pulse number Pn10P
Voltage protection level Up≤1500V
Response time≤25ns
Backup protectionBuilt-in power-frequency short-circuit protector
Power-frequency short-circuit current Isc100A (+10%)
Short-circuit breaking time0.9 ~ 1.5s
Degree of protectionIP20
Protection modesL, N-PE / L1, L2, L3 / L1, L2, L3, N-PE
Mounting35mm DIN rail, pluggable module
Remote signallingNone
Certification:CE / CMA / CNAS accredited laboratory | Price & Lead Time:Request a quote

Models & Selection

ParameterZL5-V-40kA/275-2PZL5-V-40kA/385-3PZL5-V-40kA/385-4P
Operating voltage Un230V400V400V
Maximum operating voltage Uc275V385V385V
Multi-pulse peak current IM40kA40kA40kA
Multi-pulse number Pn10P10P10P
Voltage protection level Up≤1500V≤1500V≤1500V
Protection modesL, N-PEL1, L2, L3 (no N)L1, L2, L3, N-PE
Response time≤25ns≤25ns≤25ns

Model naming rule:ZL5-V-40kA/275-2P ZL5-V-40kA/385-3P ZL5-V-40kA/385-4P

Installation

Dimensional drawing
Dimensional drawing - Pluggable Multi-Pulse Surge Protective Device
Terminal layout
Terminals: supply side L1/L2/L3, N, PE; communication and signal terminals are wired as marked on the device.

FAQ

How does a multi-pulse SPD differ from a standard SPD?

A multi-pulse SPD is tested to 10 pulses, rated Pn 10P, at a peak current of 40kA. It is intended for locations with frequent thunderstorms and repeated strikes, where a single-pulse rating would not describe the real duty.

What is the benefit of the built-in backup protection?

The built-in power-frequency short-circuit protector is rated Isc 100A with a breaking time of 0.9~1.5s. No external circuit breaker is needed upstream of the SPD, which saves space inside the enclosure.

What are the Up and response time values?

The voltage protection level Up is ≤1500V and the response time is ≤25ns. The same Up figure applies to the 2P, 3P and 4P versions, so downstream coordination can be calculated on one value.

Which models and protection modes are available?

ZL5-V-40kA/275-2P covers L, N-PE; ZL5-V-40kA/385-3P covers L1~L3 without N; ZL5-V-40kA/385-4P covers L1~L3 plus N-PE. All three share a 40kA multi-pulse peak current and ≤25ns response.

What certification applies and how is pricing provided?

Certification is held through a CE / CMA / CNAS accredited laboratory. Price and lead time are quoted per model and quantity; Request a quote with the model code and the protection mode required.