DDSU1589 Single-Phase Electronic Energy Meter
Used for suitable single-phase electrical or sub-metering points; protocol and functions are confirmed by model
The key to integrated water, electricity and gas supervision is unified meter records, units, multipliers, time periods and data responsibility. DDSU1589 and ZSA are used for confirmed electrical metering, CW aggregates electrical data and third-party water and gas meter data, and FEXLINK organizes media, areas and reports. The protocols, units, metering boundaries and anomaly handling of water and gas meters must be confirmed meter by meter; not every third-party meter should be assumed to connect directly.
The solution focuses on a multi-media data dictionary and connection governance. It suits integrated energy supervision in parks, buildings or enterprises.
Used for suitable single-phase electrical or sub-metering points; protocol and functions are confirmed by model
Three-phase metering models are selected per project; the whole series must not be treated as having identical capability
Aggregates electrical meters and confirmed third-party water and gas meter data
Builds the media, device, unit, area, report and permission structure
DDSU1589, ZSA and third-party water and gas meters provide multi-media data.
CW performs field aggregation, protocol conversion and buffering.
FEXLINK unifies the media dictionary, time periods and reports.
Energy staff reconcile data by medium, area and device.
DDSU1589, ZSA and third-party water and gas meters provide multi-media data.
DDSU1589 Single-Phase Electronic Energy Meter · ZSA Embedded Multi-Function Smart Meter
Each medium and meter has a unique device record
The solution does not commit to compatibility with all third-party water and gas meters
No. Protocol, interface, registers, units and acquisition method must be checked; some meters may need an additional gateway.
The platform should retain original units and conversion rules, and integrated reports use confirmed unified definitions.
Retain the original period and document the aggregation method. Incomplete data must not be used directly for year-on-year comparison.
Yes, but the source, the person entering it, the time and the review record should be labelled.
Through communication status, continuous zero values, jumps and comparison with historical trends, then reviewed by the responsible person.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.