Home / Solutions / Tenant Prepayment and Remote Switching Metering

Tenant Prepayment and Remote Switching Metering

A tenant prepayment scheme consists of metering, billing rules, remote control, local protection and audit records working together. Meters handle energy and prepayment-related information, the platform handles accounts, tariffs and records, and remote switching must be governed by permissions and policies while retaining the local protection provided by breakers or protective devices. Before formal use for billing, the metering instruments, tariffs, dispute handling and local regulatory requirements must also be confirmed.

Energy DataMetering Acquisition

Solution overview

The solution targets parks, commercial buildings and multi-tenant sites, with the goal of making tenant consumption metered, traceable and manageable by rule. It does not commit to specific tariffs or settlement legality, but establishes the basic chain from the circuit register and prepayment status to remote control and operation audit.

Applicable industries

  • Industrial parks
  • Commercial buildings

Primary user roles

  • Park operations
  • Financial settlement
  • Electrical O&M

Problems addressed

  • Tenant consumption needs prepayment, tariffs, remote switching and account evidence without bypassing local electrical protection
  • Tenant, circuit and meter mappings are unclear, which causes data ownership errors after re-letting or merging units
  • Remote disconnection authority, approval and operation records are incomplete

Recommended product combination

DTSY1889

DTSY1889 Three-Phase Prepaid Energy Meter

Handles three-phase four-wire tenant metering and, depending on model range, prepayment, tariff and relay control capability; specific electrical parameters and communication are confirmed against the datasheet

CW

CW Edge Computing Gateway

Aggregates meter data, connects remote switching commands with the platform, and buffers data according to policy during network anomalies

FEXLINK

FEXLINK IoT Platform

Maintains tenants, accounts, metering points and tariff rules, and records prepayment status, switching operations and audit logs

System architecture and data flow

Tenant Prepayment and Remote Switching Metering System TopologyFour-layer data flow across perception, edge control, platform and application for Tenant Prepayment and Remote Switching Metering.01Perception layer
Each tenant or separately billed unit is fitted with a matching three-phase prepayment meter, and the circui…
02Edge / control layer
CW handles meter connection and remote communication;switching commands are issued only after platform permi…
03Platform layer
FEXLINK maintains accounts, tariffs, balances, operation records and anomaly handling;a page balance is not…
04Application layer
Tenant status and anomalies for operations, reconciliation exports for finance, and circuit and protection s…

Perception layer

Each tenant or separately billed unit is fitted with a matching three-phase prepayment meter, and the circuit, tenant and meter unique code are registered

Edge / control layer

CW handles meter connection and remote communication; switching commands are issued only after platform permission and policy checks

Platform layer

FEXLINK maintains accounts, tariffs, balances, operation records and anomaly handling; a page balance is not treated as a formal financial voucher

Application layer

Tenant status and anomalies for operations, reconciliation exports for finance, and circuit and protection status for electrical O&M

Data flow

  1. A unique binding is established between tenant and metering point, recording meter number, circuit, multiplier and effective date
  2. The meter periodically uploads energy, prepayment-related status and communication status
  3. The platform forms account records according to the confirmed tariff rules and routes anomalies to a verification list
  4. When remote switching is required, an authorized role initiates it and the platform records the object, reason, approval and execution result
  5. On re-letting, lease termination or meter replacement, historical bindings are retained so that earlier billing periods are not overwritten

Integration and interfaces

  • DTSY1889 can connect through a project-confirmed DL/T 645 or Modbus-RTU interface; protocol version, registers and control authority must be verified
  • MQTT or HTTP API confirmed by the project can be used between CW and the platform
  • When connecting to financial or leasing systems, define the account key, tariff source, reconciliation period and reversal rules
  • Remote switching must be coordinated with the electrical design of breakers, contactors and protection circuits and must not alter existing protection settings

Applicable standards

  • Applicable project standards for electrical metering, prepaid consumption management and LV distribution; the final edition is confirmed against project location, industry and project documents
  • Meter communication uses project-confirmed DL/T 645 or Modbus-RTU; platform interfaces are defined per project

Acceptance and delivery boundaries

Suggested acceptance dimensions

  • Check the one-to-one mapping of tenant, room, circuit, meter, multiplier and effective date
  • Use test accounts to validate prepayment status, tariff switching, balance changes and record continuity
  • Complete the approval test before disconnecting loads for which safe disconnection conditions are not established, and verify remote switching authority, execution feedback and audit logs
  • Simulate network loss, meter replacement and re-letting, and check that historical billing periods and operation records are not overwritten

Limitations and exclusions

  • Platform balances and billing records are not automatically equivalent to recognized financial revenue or a statutory settlement voucher
  • Remote switching cannot bypass breakers, residual current protection or other local protective devices
  • Before disconnecting fire, medical, security or critical production loads, safety approval and dedicated design are mandatory
  • Tariffs are provided and confirmed by the project; this public description contains no actual tariff or commercial terms

Operational value

  • Establishes a traceable mapping between tenant consumption, account rules and circuit objects
  • Reduces inconsistency from manual reading, manual calculation and verbal switching instructions
  • Improves the verifiability of remote operations through permissions and audit records

Selection guidance

  • Confirm first whether the tenant metering unit is single-phase or three-phase, and the circuit rated current, wiring method and installation space
  • Prepayment, relay control and tariff capability must be tied to the specific DTSY1889 model; all functions cannot be assumed available from the series name
  • For formal settlement, confirm metering instruments, calibration, invoicing, dispute handling and regulatory requirements before defining the platform boundary
  • Remote switching must include approval, least privilege, failure handling and an on-site manual reset process

Typical implementation patterns

  • Typical implementation pattern: a park configures prepayment meters for independently billed tenant circuits, connects them through a gateway to the platform, maintains accounts and switching records through the tenant-to-metering-point binding, and validates data ownership with re-letting, meter replacement and network-loss scenarios. This is an anonymized typical pattern and does not represent specific customer settlement or commercial arrangements.

Before retrofit → With the solution

Before retrofit

  • Tenant consumption needs prepayment, tariffs, remote switching and account evidence without bypassing local electrical protection
  • Tenant, circuit and meter mappings are unclear, which causes data ownership errors after re-letting or merging units
  • Remote disconnection authority, approval and operation records are incomplete

With the solution

  • Establishes a traceable mapping between tenant consumption, account rules and circuit objects
  • Reduces inconsistency from manual reading, manual calculation and verbal switching instructions
  • Improves the verifiability of remote operations through permissions and audit records

How to evaluate the effect

01

Measurable signal

Each tenant or separately billed unit is fitted with a matching three-phase prepayment m…

02

Data source

DTSY1889 Three-Phase Prepaid Energy Meter · CW Edge Computing Gateway

03

Review method

Check the one-to-one mapping of tenant, room, circuit, meter, multiplier and effective date

04

Acceptance boundary

Platform balances and billing records are not automatically equivalent to recognized financial revenue or a statutory settlement voucher

Frequently asked questions

Can a prepayment meter disconnect power automatically?

Models with the corresponding control capability can switch after a rule triggers, but load type, protection circuits, authority and approval must be confirmed. Remote control cannot replace local electrical protection.

Can the balance recorded by the platform serve directly as a financial account?

Usually not directly. Financial posting, invoicing and settlement rules must match the finance system and local requirements; platform records are better treated as metering and operation evidence.

Are historical consumption records lost after re-letting?

A well-designed system keeps time-segmented bindings between metering point and tenant, and creates a new relation on re-letting without overwriting earlier periods. The actual behaviour must be verified in the platform configuration.

Can remote disconnection still work during a network outage?

It depends on the meter, gateway and platform link. Remote commands usually cannot arrive immediately during an outage; whether the meter retains local prepayment control behaviour must be confirmed by model and configuration.

Can it connect to a leasing system?

Yes, through a project-confirmed interface. Tenant key, room, lease term, tariff source and reversal process must be defined to avoid duplication or conflict between systems.

Request a matched product combination and project review

Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.

Contact FEXLINK