Home / Solutions / Grounding Monitoring for Gas Storage, Distribution and Peak-Shaving Facilities

Grounding Monitoring for Gas Storage, Distribution and Peak-Shaving Facilities

Grounding monitoring for gas storage, distribution and peak-shaving facilities should cover representative grounding points of substations, cabinet rooms and ancillary facilities, prioritizing an FR-01311, FRP and FG combination that can run independently and has local-alarm and backend-integration capabilities. Grounding-grid structure, auxiliary electrodes, hazardous areas and communication conditions require on-site confirmation; online data does not replace periodic testing.

Lightning Protection & GroundingGrounding Monitoring

Solution overview

This solution focuses on the auditability of grounding states of key utility facilities. Independent operation and visible alarms are the architectural focus, and backend integration should not be the only alarm path.

Applicable industries

  • Gas and Utilities

Primary user roles

  • Lightning Protection Engineer
  • Electrical Operations and Maintenance
  • Project Integrator

Problems addressed

  • Substations and ancillary facilities are scattered, and grounding states rely on periodic manual testing.
  • Key stations need independent alarms and traceable records; a cloud-only view is insufficient to cover network-disconnection scenarios.

Recommended product combination

FEXLINK

FEXLINK IoT Platform

Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.

FRP

FRP Loop-Method Grounding Resistance Monitor

Used for loop-method grounding resistance or grounding continuity monitoring; installation method, range, protection and explosion-proof conditions are verified by the specific model.

System architecture and data flow

Grounding Monitoring for Gas Storage, Distribution and Peak-Shaving Facilities System TopologyFour-layer data flow across perception, edge control, platform and application for Grounding Monitoring for Gas Storage, Distribution and Peak-Shaving Facilities.01Perception layer
Configure FR-01311 or FRP according to grounding-grid conditions, forming monitoring at representative groun…
02Edge / control layer
FG aggregates within the station and supports local alarms and backend communication.
03Platform layer
FEXLINK stores measurement-point trends, alarms, verification and O&M records.
04Application layer
In-station personnel handle local anomalies, while logistics or a regional center verifies historical trends…

Perception layer

Configure FR-01311 or FRP according to grounding-grid conditions, forming monitoring at representative grounding points.

Edge / control layer

FG aggregates within the station and supports local alarms and backend communication.

Platform layer

FEXLINK stores measurement-point trends, alarms, verification and O&M records.

Application layer

In-station personnel handle local anomalies, while logistics or a regional center verifies historical trends.

Data flow

  1. A grounding point's state changes.
  2. FR-01311 or an applicable FRP acquires the monitoring data.
  3. FG completes local aggregation and alarm output.
  4. The platform receives the data and retains handling records.

Integration and interfaces

  • Confirm the grounding-grid structure, auxiliary electrodes and accessibility of measurement points.
  • Clarify local alarms, backend integration and network-disconnected operation modes.
  • When integrating with a station-control or O&M platform, retain an independent alarm channel.

Applicable standards

  • GB 50057 Design Code for Lightning Protection of Buildings (applicable clauses and version to be confirmed by the project location and design documents)
  • GB/T 21431 Technical Code for Inspection of Lightning Protection Devices (final version and test method to be confirmed by the project)

Acceptance and delivery boundaries

Suggested acceptance dimensions

  • Measurement points establish a unique correspondence with the station, facility and grounding-grid area.
  • Both local and backend alarms can work independently.
  • Anomaly, offline and manual-verification records are complete.

Limitations and exclusions

  • Online monitoring cannot replace statutory grounding testing and lightning-protection testing.
  • A single-point trend does not represent the entire grounding-grid state.
  • Hazardous-area installation and certificate requirements require separate review.

Operational value

  • Improves the continuous visibility of grounding states at key stations.
  • Retains local alarms even when the network is disconnected.
  • Forms auditable historical records.

Selection guidance

  • When auxiliary-electrode conditions are available, evaluate the FR-01311 three-electrode method.
  • When conditions are unavailable, evaluate the FRP loop method and verify the specific model.
  • Select FG communication and local output methods according to the in-station network and alarm process.

Typical implementation patterns

  • A typical implementation pattern first sets representative measurement points at a substation and verifies local alarms.
  • Another pattern integrates station by station in batches, forming a historical view at the regional center.

Before retrofit → With the solution

Before retrofit

  • Substations and ancillary facilities are scattered, and grounding states rely on periodic manual testing.
  • Key stations need independent alarms and traceable records; a cloud-only view is insufficient to cover network-disconnection scenarios.

With the solution

  • Improves the continuous visibility of grounding states at key stations.
  • Retains local alarms even when the network is disconnected.
  • Forms auditable historical records.

How to evaluate the effect

01

Measurable signal

Configure FR-01311 or FRP according to grounding-grid conditions, forming monitoring at…

02

Data source

FR-01311 Grounding Resistance Online Tester (Three-Electrode Method) · FG Smart Gateway (Zigbee, RS485 & Ethernet)

03

Review method

Measurement points establish a unique correspondence with the station, facility and grounding-grid area.

04

Acceptance boundary

Online monitoring cannot replace statutory grounding testing and lightning-protection testing.

Frequently asked questions

Can alarms still occur after the network is disconnected?

The solution prioritizes local-alarm capability; the specific output method and power-supply conditions are confirmed by the device model.

Can only a cloud platform be used for management?

Using the cloud platform as the only alarm path is not recommended; key stations should retain locally visible states.

Why does one station have more than one measurement point?

Different facilities and grounding-grid areas may be independent, and the number of representative measurement points should be determined by the on-site structure.

What devices does "grounding monitoring for gas storage, distribution and peak-shaving facilities" typically consist of?

FR-01311: uses the three-electrode method for online grounding resistance monitoring, requiring grounding-grid structure and auxiliary-electrode installation conditions; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project; FRP: used for loop-method grounding resistance or grounding continuity monitoring, with installation method, range, protection and explosion-proof conditions verified by the specific model.

What site conditions should be verified before implementing "grounding monitoring for gas storage, distribution and peak-shaving facilities"?

When auxiliary-electrode conditions are available, evaluate the FR-01311 three-electrode method; when conditions are unavailable, evaluate the FRP loop method and verify the specific model; select FG communication and local output methods according to the in-station network and alarm process.

Request a matched product combination and project review

Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.

Contact FEXLINK