FR-01311 Grounding Resistance Online Tester (Three-Electrode Method)
Uses the three-electrode method for online grounding resistance monitoring, requiring grounding-grid structure and auxiliary-electrode installation conditions.
Grounding monitoring for gas storage, distribution and peak-shaving facilities should cover representative grounding points of substations, cabinet rooms and ancillary facilities, prioritizing an FR-01311, FRP and FG combination that can run independently and has local-alarm and backend-integration capabilities. Grounding-grid structure, auxiliary electrodes, hazardous areas and communication conditions require on-site confirmation; online data does not replace periodic testing.
This solution focuses on the auditability of grounding states of key utility facilities. Independent operation and visible alarms are the architectural focus, and backend integration should not be the only alarm path.
Uses the three-electrode method for online grounding resistance monitoring, requiring grounding-grid structure and auxiliary-electrode installation conditions.
Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.
Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.
Used for loop-method grounding resistance or grounding continuity monitoring; installation method, range, protection and explosion-proof conditions are verified by the specific model.
Configure FR-01311 or FRP according to grounding-grid conditions, forming monitoring at representative grounding points.
FG aggregates within the station and supports local alarms and backend communication.
FEXLINK stores measurement-point trends, alarms, verification and O&M records.
In-station personnel handle local anomalies, while logistics or a regional center verifies historical trends.
Configure FR-01311 or FRP according to grounding-grid conditions, forming monitoring at…
FR-01311 Grounding Resistance Online Tester (Three-Electrode Method) · FG Smart Gateway (Zigbee, RS485 & Ethernet)
Measurement points establish a unique correspondence with the station, facility and grounding-grid area.
Online monitoring cannot replace statutory grounding testing and lightning-protection testing.
The solution prioritizes local-alarm capability; the specific output method and power-supply conditions are confirmed by the device model.
Using the cloud platform as the only alarm path is not recommended; key stations should retain locally visible states.
Different facilities and grounding-grid areas may be independent, and the number of representative measurement points should be determined by the on-site structure.
FR-01311: uses the three-electrode method for online grounding resistance monitoring, requiring grounding-grid structure and auxiliary-electrode installation conditions; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project; FRP: used for loop-method grounding resistance or grounding continuity monitoring, with installation method, range, protection and explosion-proof conditions verified by the specific model.
When auxiliary-electrode conditions are available, evaluate the FR-01311 three-electrode method; when conditions are unavailable, evaluate the FRP loop method and verify the specific model; select FG communication and local output methods according to the in-station network and alarm process.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.
Contact FEXLINK