FS SPD Monitoring Module
Used to collect telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are to be confirmed by the FS model.
Lightning protection and grounding monitoring for railway and rail transit signal rooms should establish points by station, room, power and signal entrances and grounding busbar zones, combining FS, FSS, FL, FR and aggregation devices. System integration must comply with signal-profession and communication-channel management requirements; any alarm serves only as an O&M clue and does not directly participate in signal control or interlocking judgment.
This solution targets lightning-protection and grounding states of scattered signal rooms. The implementation focus is controllable communication channels, clear point boundaries and executable construction windows.
Used to collect telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are to be confirmed by the FS model.
As an integrated smart SPD combining protection and condition monitoring, it is selected by number of poles, protection parameters and circuit conditions.
Records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet.
As a grounding monitoring product family, select the applicable model by the three-electrode method, the loop method or specific on-site grounding-grid conditions.
Configure monitoring devices at the power entrance, signal entrance, grounding busbar and room-environment-related locations.
In-station aggregation devices acquire and cache data according to professional network rules.
The platform displays states, events and offline information by line, station and room.
Maintenance personnel verify anomalies within approved windows and record handling results according to the prescribed process.
Configure monitoring devices at the power entrance, signal entrance, grounding busbar an…
FS SPD Monitoring Module · FSS Smart Surge Protective Device (Flagship)
Points establish a unique relationship with line, station, room and professional equipment.
The monitoring system does not participate in signal control, interlocking judgment or automatic handling.
This solution only collects approved monitoring information and is isolated from the signal control network; professional approval and commissioning must still be completed before implementation.
This solution does not perform automatic cut-off. Protection and control actions are executed by existing professional systems.
Whether caching is available depends on the selected aggregation device; storage and retransmission capabilities must be confirmed during selection.
FS: collects telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are confirmed by the FS model; FSS: as an integrated smart SPD combining protection and condition monitoring, selected by number of poles, protection parameters and circuit conditions; FL: records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet; FR: as a grounding monitoring product family, select the applicable model by the three-electrode method, the loop method or specific on-site grounding-grid conditions.
Select FS or FSS according to the existing SPD interfaces at the power and signal entrances; select FL and FR models according to down conductors, grounding busbar and station environment; prioritize an aggregation method that can be installed within the maintenance window and supports local caching.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.
Contact FEXLINK