Home / Solutions / Lightning Protection Monitoring for Airport Terminals and Navigation-Aid Facilities

Lightning Protection Monitoring for Airport Terminals and Navigation-Aid Facilities

Lightning protection monitoring for airport terminals and navigation-aid facilities should split objects by building, airfield area and facility type, establishing zoned inventories of SPD, lightning and grounding. The combination of FS, FSS, FL, FR and platform forms a unified O&M view, but multi-system integration, non-interruption construction and applicability of professional standards must be confirmed by airport project documents.

Lightning Protection & GroundingLightning Protection Monitoring

Solution overview

This solution addresses the scattered protection states of terminals, hangars, airfield power distribution and navigation-aid facilities. Implementation should not pursue full coverage at once; key areas and constructable windows should be determined first.

Applicable industries

  • Airports

Primary user roles

  • Airport Electrical O&M
  • Weak-Current System Engineer
  • Project Integrator

Problems addressed

  • Terminals, hangars, airfield power distribution and navigation-aid facilities belong to different systems, with scattered lightning-protection states.
  • There are many construction areas and strong operational constraints, making generic configurations difficult to apply directly.

Recommended product combination

FS

FS SPD Monitoring Module

Used to collect telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are to be confirmed by the FS model.

FR

FR Grounding Resistance Monitoring Module

As a grounding monitoring product family, select the applicable model by the three-electrode method, the loop method or specific on-site grounding-grid conditions.

System architecture and data flow

Lightning Protection Monitoring for Airport Terminals and Navigation-Aid Facilities System TopologyFour-layer data flow across perception, edge control, platform and application for Lightning Protection Monitoring for Airport Terminals and Navigation-Aid Facilities.01Perception layer
Configure FS, FSS, FL and FR monitoring points by building or airfield area to form zoned acquisition.
02Edge / control layer
Each zone uses FG or a confirmed gateway for aggregation, maintaining network isolation.
03Platform layer
The platform organizes data by terminal, airfield area, facility and responsible person.
04Application layer
The O&M team confirms alarms by area and arranges verification in combination with the airport operation pla…

Perception layer

Configure FS, FSS, FL and FR monitoring points by building or airfield area to form zoned acquisition.

Edge / control layer

Each zone uses FG or a confirmed gateway for aggregation, maintaining network isolation.

Platform layer

The platform organizes data by terminal, airfield area, facility and responsible person.

Application layer

The O&M team confirms alarms by area and arranges verification in combination with the airport operation plan.

Data flow

  1. Lightning-protection facilities of a building or airfield area produce state changes.
  2. The corresponding monitoring device collects SPD, lightning current or grounding data.
  3. Zoned aggregation devices upload according to airport network rules.
  4. The platform forms area alarms and maintenance records.

Integration and interfaces

  • Confirm the boundaries of existing monitoring, network and O&M systems of each building and airfield area.
  • Clarify construction approval, power outage/restoration windows and equipment responsible units.
  • Different professional interfaces must provide point lists, protocols and test conditions.

Applicable standards

  • MH/T standards related to airport lightning protection and grounding (applicable version to be confirmed by airport professional design documents)
  • GB 50057 Design Code for Lightning Protection of Buildings (applicable clauses to be confirmed by the project location)

Acceptance and delivery boundaries

Suggested acceptance dimensions

  • Monitoring points establish a correspondence with airport area, building, system and responsible person.
  • Zoned alarms can be confirmed independently, with one zone's offline not affecting other zones' records.
  • Installation and test records meet airport project and change management requirements.

Limitations and exclusions

  • A single platform view cannot replace the operational responsibility of each professional system.
  • Without construction and operational approval, integration of key areas should not proceed.
  • Facilities not covered by a zone cannot be inferred to be in a normal state.

Operational value

  • Establishes a lightning-protection state inventory across buildings and airfield areas.
  • Supports arranging inspection and construction verification by area.
  • Provides unified event records for multi-system collaborative O&M.

Selection guidance

  • First divide monitoring boundaries by terminal, hangar, airfield power distribution and navigation-aid facilities.
  • Select FSS or FS for new and existing circuits respectively.
  • Lightning-current and grounding products are confirmed point by point according to down conductors, grounding grid and installation environment.

Typical implementation patterns

  • A typical implementation pattern is to first select one power-distribution zone of the terminal and one airfield-area facility for piloting.
  • Another pattern is to integrate by operational area in batches, maintaining unified alarm coding.

Before retrofit → With the solution

Before retrofit

  • Terminals, hangars, airfield power distribution and navigation-aid facilities belong to different systems, with scattered lightning-protection states.
  • There are many construction areas and strong operational constraints, making generic configurations difficult to apply directly.

With the solution

  • Establishes a lightning-protection state inventory across buildings and airfield areas.
  • Supports arranging inspection and construction verification by area.
  • Provides unified event records for multi-system collaborative O&M.

How to evaluate the effect

01

Measurable signal

Configure FS, FSS, FL and FR monitoring points by building or airfield area to form zone…

02

Data source

FS SPD Monitoring Module · FSS Smart Surge Protective Device (Flagship)

03

Review method

Monitoring points establish a correspondence with airport area, building, system and responsible person.

04

Acceptance boundary

A single platform view cannot replace the operational responsibility of each professional system.

Frequently asked questions

Can terminals and navigation-aid facilities share one set of alarm rules?

Direct sharing is not recommended. The two differ in operational responsibility and risk boundaries, and should have independent zones and alarm levels.

Does construction require halting air operations?

Usually the impact on operations should be reduced through zoning and window management; specific requirements are determined by airport approval.

Who provides the point list for multi-system integration?

It is jointly confirmed by the owners of each system, and the platform implementer is responsible for mapping and commissioning records.

What devices does "lightning protection monitoring for airport terminals and navigation-aid facilities" typically consist of?

FS: collects telemetry signals, circuit breaker, grounding or lightning strike count states from existing SPDs; specific capabilities, power supply and communication suffixes are confirmed by the FS model; FSS: as an integrated smart SPD combining protection and condition monitoring, selected by number of poles, protection parameters and circuit conditions; FL: records events such as lightning current peak and energy; indoor/outdoor model, range, protection rating and installation orientation are confirmed by the datasheet; FR: as a grounding monitoring product family, select the applicable model by the three-electrode method, the loop method or specific on-site grounding-grid conditions.

What site conditions should be verified before implementing "lightning protection monitoring for airport terminals and navigation-aid facilities"?

First divide monitoring boundaries by terminal, hangar, airfield power distribution and navigation-aid facilities; select FSS or FS for new and existing circuits respectively; lightning-current and grounding products are confirmed point by point according to down conductors, grounding grid and installation environment.

Request a matched product combination and project review

Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.

Contact FEXLINK