ESA SMART METER

The ESA Multi-Parameter Smart Meter

Full-Parameter Electrical Smart Module

Integrates power metering, power quality analysis, and smart control. Supports multi-protocol access, providing full-parameter sensing for refined energy data management and smart O&M. Exclusive software self-calibration ensures accuracy remains stable for 10+ years.

Full-Parameter Data Acquisition Voltage/current/power/harmonics/power factor and other full-parameter monitoring
Multi-Protocol Seamless Access RS485/Modbus standard protocol, compatible with SCADA/BA/EMS
Smart Logic Alarm 8 alarm sources "AND/OR" logic programming, automatic linkage response

Product Overview

Product Overview

The ESA Multi-Parameter Smart Meter uses a dedicated metering chip and high-precision sensors to achieve dynamic sensing of up to 40+ variables. Dedicated to Low-Voltage three-phase circuit electrical parameter monitoring, can monitor Voltage, Current, power, power factor, energy consumption and other parameters. Supports over-voltage, over-current, phase loss, DI linkage and other alarm outputs. Exclusive software self-calibration ensures accuracy remains stable throughout the service life (typically 10+ years), avoiding "data depreciation" and replacement costs due to accuracy degradation.

Class 0.2S Core Measurement Accuracy
40+ Dynamic Sensing Variables
200+ Open Data Registers
10 years+ Accuracy No Decay

Product Features

Key Features

Comprehensive Monitoring

Monitors three-phase voltage/current (external CT), frequency, three-phase power, total power (active, reactive, apparent), three-phase power factor and other full parameters

Key Parameters Expansion

High-speed chips capture key parameters accurately, quickly, and stably, enabling early prediction while adding more parameters, supports 0-2000A metering

All-Climate Sensor

Non-contact split-core sensors operate stably under strong electromagnetic interference

Comprehensive Output Alarm

Output alarm status normal, can write control output alarm settings: open/close, configurable control

Compact and Flexible

Supports linkage control; standard OLED display and physical buttons for convenient on-site query and configuration; RS485 communication, Modbus; 36mm compact width

High Accuracy

Default Class 0.5, with split-core sensors up to Class 0.2s, current monitoring range 0-6000A

Product Advantages

Product Advantages
Class 0.2S

Permanent Online Accuracy

Core measurement accuracy reaches Class 0.2S, far exceeding common Class 1.0 meters. Exclusive software self-calibration enables remote or local calibration after accuracy drift, reducing maintenance costs by 90%.

60%

All-in-One

70+ electrical data parameters, DC5V/AC220V dual Power Supply, integrated 2-channel DI/1-channel DO/RS485. Highly integrated design replaces multiple devices in traditional solutions, improving installation efficiency by 50%.

80%

Smart Sentinel

From monitoring, alarm to automated response. Supports auto-linkage of 8 alarm sources, going beyond simple threshold alarms to enable complex logic such as "overcurrent AND door open", and auto-starts fans and alarms.

200+

Complete Data Dictionary

Complete address table with 200+ readable/writable registers. All parameters, data, and settings are fully transparent. Standard Modbus-RTU protocol enables direct access from SCADA/BA/EMS/cloud platforms.

0.1s

Ultimate Interactive Experience

High-brightness OLED display with smart menu, red/green/pulse tri-color independent indicators. Device status and alarm categories can be accurately identified within 0.1s from 10 meters away.

50,000h

Wide-Temperature Reliable Operation

-20°C~60°C wide-temperature operation, UL94V0 flame-retardant material, 50,000 hours MTBF. Pluggable terminals enable tool-free wiring, improving efficiency by 80%.

Selection Guide

Model Selection Guide
ESA -
1
2
3
4
5
-
R

Position 1 · Power

1=DC5V
2=AC220V

Position 2 · Display

1=7-segment
2=OLED

Position 3 · Wiring

1=Three-phase four-wire

Position 4 · Current Parameter

1=0~5A
2=0~100A
3=0~400A
4=0~600A

Position 5 · I/O

1=1-channel relay output
2-channel digital input

R · Communication

RS485

Selection Table

Model Power Supply Display Current Voltage Other Parameters DI Inputs Relay Output RS485 MODBUS
ESA-12111-R DC5V OLED 0~5A 220/380V All Parameters 2-channel 1-channel Yes
ESA-12121-R DC5V OLED 0~100A 220/380V All Parameters 2-channel 1-channel Yes
ESA-12131-R DC5V OLED 0~400A 220/380V All Parameters 2-channel 1-channel Yes
ESA-12141-R DC5V OLED 0~600A 220/380V All Parameters 2-channel 1-channel Yes
ESA-22111-R AC220V OLED 0~5A 220/380V All Parameters 2-channel 1-channel Yes
ESA-22121-R AC220V OLED 0~100A 220/380V All Parameters 2-channel 1-channel Yes
ESA-22131-R AC220V OLED 0~400A 220/380V All Parameters 2-channel 1-channel Yes
ESA-22141-R AC220V OLED 0~600A 220/380V All Parameters 2-channel 1-channel Yes

Other electrical parameters include: frequency, power, power factor, etc.

Technical Parameters

Technical Specifications

Basic Parameters

Parameter Specification
Operating VoltageDC 4.75~5.25V(5V) / AC 180~250V(220V)
Operating Temperature-20℃ ~ 60℃
Weight150g
Enclosure MaterialThermoplastic UL94V0
MountingStandard 35mm DIN rail
CommunicationRS485
Power Consumption≤2W
Operating Humidity<95%
Dimensions36×110×69mm(L×W×H)
Protection RatingIP20
DisplayOLED
ProtocolModbus

Monitoring Functions

Parameter Specification
Voltage (AC)Rated 220V/380V, overload 1.2x (continuous)/2x (1s), Accuracy Class 0.5/0.2s
Current (AC)Rated 5A/100A/400A/600A, overload 1.2x (continuous)/2x (1s), Accuracy Class 0.5/0.2s
Frequency45~65Hz, accuracy 0.01Hz
Active EnergyAccuracy Class 1
Reactive EnergyAccuracy Class 2
DI InputDry contact input, built-in power
DO OutputRelay output, contact capacity AC250V/3A DC30V/3A, normally open contact

Installation Instructions

Installation Guide

Installation Dimensions

Dimensions
The ESA Multi-Parameter Smart Meter Installation dimensions

Standard 35mm DIN rail mounting, Dimensions: 36×110×69mm(L×W×H)

Sensor Description

Sensor Description

5A Sensor

Current Ratio 5A/0.33V

Aperture 16mm

100A Sensor

Current Ratio 100A/0.33V

Aperture 24mm

400A Sensor

Current Ratio 400A/0.33V

Aperture 36mm

600A Sensor

Current Ratio 600A/0.33V

Aperture 36mm

Interface Diagram

Interface Description
The ESA Multi-Parameter Smart Meter Interface Diagram

Power Terminal

L1Live wire AC220V Power Supply
NNeutral AC220V Power Supply
5VDC5V Power Supply
GND0V DC5V Power Supply

Note: 220V AC and 5V DC are mutually exclusive

RS485 Communication

A terminalRS485 A signal
B terminalRS485 B signal

DI Input

DI1Other end connects to GND, direction-independent
DI2Other end connects to GND, direction-independent

DO Output

DO1Relay output, direction-independent
DO1'Relay output, direction-independent

Current

IA+ / IA-A-phase Current
IB+ / IB-B-phase Current
IC+ / IC-C-phase Current

Voltage

L1A-phase Voltage
L2B-phase Voltage
L3C-phase Voltage
NNeutral wire

Key Points

  • Definition: The ESA Smart Meter is FEXLINK's smart-meter variant of the ESA Electrical Safety Monitoring Terminal with integrated power/energy metering.
  • Core Capabilities: Adds active/reactive energy, demand and other metering functions on top of residual current, temperature and voltage monitoring, supporting energy analysis.
  • Scenarios: Suitable for distribution cabinets, commercial complexes and industrial parks where electrical safety and energy management are equally important.
  • Related Products: ESA Electrical Safety Terminal, SFA Multi-Element Controller, ZSA Embedded Multi-Function Meter.

Frequently Asked Questions

Product FAQ

What is ESA Smart Meter?

The ESA Smart Meter is FEXLINK's smart-meter variant of the ESA Electrical Safety Monitoring Terminal with integrated power/energy metering.

What scenarios does ESA Smart Meter apply to?

Suitable for distribution cabinets, commercial complexes and industrial parks where electrical safety and energy management are equally important.

How does ESA Smart Meter differ from traditional solutions?

Compared with the standard ESA, the smart-meter variant adds energy metering and energy analysis, offering multi-purpose use and saving installation space.

How is ESA Smart Meter installed and integrated?

DIN-rail mount inside the distribution cabinet, connect voltage/current transformers and residual-current CTs, and wire the RS485 bus.

How can I purchase FEXLINK products or request a demo?

Submit requirements via the Contact page on the FEXLINK website, or call +86-755-8653-6148 to request a demo and selection consultation; engineers will propose a matched solution and quotation based on your scenario.

FEXLINK Business Scope

FEXLINK specializes in smart lightning protection and electrical safety, offering a product portfolio covering lightning protection, lightning online monitoring, lightning protection online monitoring, lightning arrester, intelligent lightning arrester, lightning arrester monitoring, grounding resistance, grounding monitoring for smart lightning protection scenarios, while addressing digital distribution, smart distribution, electricity meter, carbon neutral, industrial internet, carbon asset for digital business, helping enterprises achieve safe, efficient and low-carbon energy management.