Direct Answer

Which number on the cockpit — total power use, unit consumption, or YoY/MoM — counts as a real anomaly? Judgment needs three reading logics: look at whether the total tracks production/load reasonably, look at whether unit consumption removes production differences, and look at whether YoY/MoM figures are normalized — reading raw power consumption alone leads to misjudgment.

A scenario: A factory's power use rises 10% this month — the manager treats it as an anomaly — but output also rises 10% — unit consumption is unchanged — it is not an anomaly, it is more production. The logic of judgment is that absolute power use fluctuates with output — look at whether unit consumption changed and whether YoY/MoM is normalized — with the three logics linked, anomalies are seen accurately.

1. What the Row of Numbers on the Cockpit Is

Number one, total power use — a total indicator: the whole plant/workshop's power use in a period; Number two, unit consumption — an efficiency indicator: energy per unit of product (kWh/piece); Number three, YoY — annual comparison: compared with the same period last year; Number four, MoM — monthly comparison: compared with the previous period; The essence of the numbers — business indicators: designed for managers to judge.

In one sentence: the cockpit numbers are totals, unit consumption, YoY and MoM — designed for business judgment.

An example: A factory cockpit: total power use 1.2 million kWh, unit consumption 0.85 kWh/piece, YoY +6%, MoM -2%. The logic is that each number answers one question — totals show scale, unit consumption shows efficiency, YoY shows the annual trend and MoM shows recent change — together they form a complete judgment.

2. Reading Logic One: Compare Total Power Use with Output

The meaning of total power use — scale: an absolute indicator of size; Why compare with output — the source of fluctuation: when output rises, power naturally rises; The method of comparison — look at the trend: if power and output move together it is normal; Judging an anomaly — divergence: it is suspicious only when power rises and output does not; The meaning of comparison — separate causes: production growth from abnormal energy use.

In one sentence: total power use is compared with output — moving together is normal, divergence is suspicious.

An example: A factory's power rises 8% — output also rises 8% — comparison confirms it is caused by production — not an anomaly. The logic is that total power is a scale indicator — it must be viewed together with output — power rising from more production is not a problem, power rising with unchanged output is.

3. Reading Logic Two: Unit Consumption Removes Production Differences

The definition of unit consumption — an efficiency indicator: total power use divided by output; The meaning of unit consumption — removing output: excluding the illusion caused by production growth; How to read it — look at the change: rising unit consumption means falling efficiency; Unit consumption anomalies — trends: continuous rise or a clear jump; The value of unit consumption — comparability: comparable across months and output levels.

In one sentence: unit consumption is the true efficiency after removing output — up means lower efficiency, down means higher efficiency.

An example: A factory's unit consumption rises from 0.85 to 0.92 kWh/piece — output unchanged — efficiency has fallen — an inspection finds aging equipment — repaired and restored. The logic is that unit consumption removes output differences — it compares efficiency rather than totals — this is the correct measure for judging energy-saving results.

4. Reading Logic Three: Normalize YoY/MoM

The meaning of YoY/MoM — trend comparison: compared with last year or the previous period; Why normalize — unified baselines: output, days and temperature differ; The method of normalization — compare unit consumption: replace totals with unit consumption; The value of normalization — comparability: excluding scale and environment differences; The reminder — raw values are not comparable: comparing absolute values directly misleads.

In one sentence: YoY/MoM are comparable only after normalization — use unit consumption instead of totals.

An example: A factory's YoY is +6% — but output also rose — using unit consumption YoY: -2% — it actually saved energy. The logic is that comparing totals directly mixes in the output factor — normalize to unit consumption first, then compare on the same basis.

5. Linking the Three Logics to Locate Anomalies

Link one, compare totals with output — look at scale: does the total rise match output; Link two, unit consumption shows efficiency — look at efficiency: a rising unit is the real problem; Link three, YoY/MoM show the trend — look at the trend: normalized, is it up or down; The order of linking — totals first, then unit consumption, then YoY/MoM; The essence of linking — filter layer by layer: remove scale factors, then anomalies surface.

In one sentence: the three logics link as totals vs output, unit consumption for efficiency and YoY for trend — filter layer by layer.

An example: A factory: total rises 10% — output also rises 10% (normal) — unit consumption +6% (anomaly) — confirmed rising after YoY normalization — located to an inefficient air compressor. The logic is that looking at totals alone is masked by production growth — link unit consumption and YoY — the efficiency anomaly surfaces.

6. Common Misreading One: More Production Means Saving Energy

The misread scenario — output and power rise: believed to be saving energy; The cause of the misread — looking at totals: not looking at unit consumption; The cost of the misread — reversed judgment: treating low efficiency as saving; The correct reading — look at unit consumption: a falling unit means saving; The root of the misread — unclear baselines: mixing totals with efficiency.

In one sentence: "more production means saving" is a misread — only a falling unit consumption means saving.

An example: A factory's output doubles and power doubles — it thinks it saved nothing — but unit consumption fell 5% — efficient growth. The logic is that totals follow output — judge saving by unit consumption — when unit consumption falls, growing output saves at the same time.

7. Common Misreading Two: Stoppage Means Lower Consumption

The misread scenario — consumption falls after a stoppage: believed to be a saving success; The cause of the misread — seeing the total fall: not seeing output fall in parallel; The cost of the misread — a false conclusion: consumption cut by stoppage has no value; The correct reading — look at unit consumption: unit consumption is often higher during a stoppage; The root of the misread — comparing only absolute values: no normalization.

In one sentence: "stoppage means lower consumption" is a misread — output falls in parallel, unit consumption may be higher.

An example: A factory stops one week in August and power falls 15% — it believes it saved — but unit consumption actually rose 3% — caused by the stoppage. The logic is that a total fall may be caused by a stoppage — normalize to unit consumption — stoppage periods are often inefficient — judge savings by unit consumption, not totals.

8. Back to YESLON: How the Tianyan E Module Helps

The E module role — energy analysis: automatically calculates totals, unit consumption and YoY/MoM; The E module capability — built-in baselines: normalization is calculated automatically; The E module presentation — the cockpit: all indicators in one view; The E module alert — anomaly recognition: unit consumption trend anomalies are flagged automatically; The E module value — accurate reading: the three logics are supported automatically.

In one sentence: the Tianyan E module automatically calculates unit consumption and built-in normalization — the cockpit reads accurately.

An example: A factory uses the Tianyan E module: unit consumption calculated automatically, YoY normalized automatically — unit consumption anomalies flagged automatically — judgment no longer relies on manual work. The logic is that the three baselines are error-prone by hand — the E module calculates them — totals, unit consumption and YoY/MoM in one view — judgment has a basis.

9. Self-Check: Three Questions for Reading Numbers Correctly

Question one, is the total compared — compare: is the total compared with output; Question two, is unit consumption viewed — unit: is efficiency viewed after removing output; Question three, is it normalized — normalize: are YoY/MoM on the same basis.

In one sentence: the three questions are compare, unit and normalize — all answered, no misjudgment.

A self-check example: A factory answers the three questions: total compared, unit viewed, YoY normalized — the reading is accurate. The way to read cockpit numbers needs three logics — look at whether the total tracks output/load reasonably, look at whether unit consumption removes production differences, and look at whether YoY/MoM are normalized — reading raw power consumption alone misleads — more production is not necessarily saving and a stoppage is not necessarily lower consumption — with the three logics linked, anomalies are seen accurately.

Scope and Limitations

  • The conclusions in this article are intended for LV distribution and electrical-safety sites. Criteria are compiled from public codes and FEXLINK product documentation, and product parameters follow the latest selection handbook and product knowledge base.
  • Quantitative criteria (protection zone, discharge and residual voltage, earth resistance, thresholds and grading) hold under the preconditions stated in this article. Where the site voltage level, earthing arrangement, environmental category or load profile differs, the figures must be recalculated. Specific configurations involving Tianyan engine, E track (energy analytics) should be verified against actual circuit parameters.
  • Specific product models and parameters are subject to the latest selection handbook and product knowledge base; this article does not constitute selection or procurement advice.
  • Standard numbers cited here refer to the currently effective editions; when a standard is revised, the related quantitative conclusions must be re-checked.
  • Deployment and implementation for specific projects must be carried out by qualified engineers based on site survey and design drawings.

Frequently Asked Questions

What Should You Actually Look At on the Energy Cockpit

Which number on the cockpit — total power use, unit consumption, or YoY/MoM — counts as a real anomaly