FSS Smart Surge Protective Device (Flagship)
As an integrated smart SPD combining protection and condition monitoring, it is selected by number of poles, protection parameters and circuit conditions.
An integrated smart SPD for new circuits should synchronously confirm rated current, protection parameters, number of poles, installation space and communication method at the design stage, then select the specific FSS model and connect to the platform via FG. This solution is suitable for integrated design of protection and condition monitoring, and is not suitable for direct replacement of an existing SPD whose mechanical and electrical compatibility has not been confirmed.
This solution moves protection, monitoring and event recording forward to new or wholly replaced circuits. The core of selection is protection parameters and on-site installation conditions; platform access cannot replace design verification.
As an integrated smart SPD combining protection and condition monitoring, it is selected by number of poles, protection parameters and circuit conditions.
Aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform.
Provides device management, alarm, historical data, permission and O&M record capabilities; the deployment method is to be confirmed by the project.
Install an applicable FSS in a new or wholly replaced circuit to form integrated protection and condition monitoring.
FG aggregates FSS states and uploads according to the project communication method.
FEXLINK displays states and events by power-distribution tier, circuit and device.
Design and O&M retain selection, installation and alarm records in the same circuit inventory.
Install an applicable FSS in a new or wholly replaced circuit to form integrated protect…
FSS Smart Surge Protective Device (Flagship) · FG Smart Gateway (Zigbee, RS485 & Ethernet)
Each FSS model is consistent with the circuit protection design.
FSS cannot replace all existing SPD monitoring modules based on its name alone.
No. Mechanical interfaces, electrical parameters, number of poles and on-site protection coordination must be verified.
The platform is used for aggregation and O&M records; whether a platform is needed depends on the project's monitoring scope.
Not enough. Imax, Up, number of poles, backup protection, installation space and communication requirements also need verification.
FSS: as an integrated smart SPD combining protection and condition monitoring, selected by number of poles, protection parameters and circuit conditions; FG: aggregates downstream lightning-protection monitoring devices, performs protocol conversion and transmits states and events to the upper-level platform; FEXLINK: provides device management, alarm, historical data, permission and O&M record capabilities, with the deployment method confirmed by the project.
Determine the number of poles and protection parameters according to the protection design, then select the FSS model lineup; select the installation structure and suffix according to in-cabinet space and communication method; existing SPDs must first have compatibility confirmed and cannot be replaced directly according to a new-circuit scheme.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.