Home / Solutions / Integrated Edge Acquisition and Local Control

Integrated Edge Acquisition and Local Control

An integrated edge architecture should place field acquisition, local logic, I/O interlocking, HMI display and remote upload in clearly defined layers. CW handles device access and communication, CC100 handles project-confirmed local control logic, I/O modules extend signals, the HMI provides the on-site interface, and FEXLINK carries remote O&M. Not every site suits a single-unit integrated design; I/O capacity, real-time behaviour, safety interlocks and network boundaries must be confirmed against the specific model and project design.

Device-Edge-Cloud CollaborationEdge ComputingControl Logic

Solution overview

The solution targets manufacturing and distribution scenarios where device stacking on site and fragmented systems are a problem. The focus is a unified acquisition model, control logic boundaries, on-site operation and remote monitoring responsibility.

Applicable industries

  • Manufacturing plants
  • Industrial and commercial distribution
  • Industrial parks

Primary user roles

  • Automation engineers
  • Electrical engineers
  • System integrators

Problems addressed

  • Field acquisition, PLC logic, I/O interlocking, local display and remote O&M are spread across different systems
  • Point tables and device status are maintained twice, and faults are hard to attribute to acquisition, control or communication
  • Monitoring alarms are coupled too tightly with local control, lacking safety boundaries and operation audit

Recommended product combination

CC100

CC100 PLC Local Controller

Carries project-confirmed local logic control; I/O and real-time capability are confirmed by specific model and technical documentation

FEXLINK

FEXLINK IoT Platform

Provides remote device, alarm, history and maintenance views and does not replace local safety protection

System architecture and data flow

Integrated Edge Acquisition and Local Control System TopologyFour-layer data flow across perception, edge control, platform and application for Integrated Edge Acquisition and Local Control.01Perception layer
Field sensors, instruments, switch status and device signals enter the edge layer through I/O or project-con…
02Edge / control layer
CC100 executes local logic while CW handles other device access and upload;control and communication respons…
03Platform layer
FEXLINK builds the device, point, alarm and maintenance model
04Application layer
The HMI serves on-site operation and the platform serves remote monitoring and O&M, while safety interlocks…

Perception layer

Field sensors, instruments, switch status and device signals enter the edge layer through I/O or project-confirmed communication interfaces

Edge / control layer

CC100 executes local logic while CW handles other device access and upload; control and communication responsibilities are configured separately

Platform layer

FEXLINK builds the device, point, alarm and maintenance model

Application layer

The HMI serves on-site operation and the platform serves remote monitoring and O&M, while safety interlocks are handled by independent or reviewed circuits

Data flow

  1. Build the list of devices, I/O, communication points, control variables and HMI objects
  2. Field signals enter the controller or gateway, where quality checks and status updates are performed
  3. Local logic issues control per confirmed conditions while recording inputs, outputs and trigger cause
  4. The gateway uploads status, alarms and necessary history to the platform and retains local logic during network loss
  5. On-site operations and remote configuration are recorded separately with permissions and audit logs

Integration and interfaces

  • Digital, analog and temperature signals connect to the corresponding I/O modules per the project point list
  • CW and field devices can use project-confirmed RS485, Modbus, Ethernet or DI/DO
  • Protocol, point table and refresh period must be confirmed between the HMI and the controller or gateway
  • Platform interfaces can use MQTT or HTTP API, with network isolation and account permissions configured per project

Applicable standards

  • Applicable project standards for industrial automation and electrical control; the final edition is confirmed against project location, industry and project documents
  • Field communication can use project-confirmed Modbus, Ethernet or DI/DO; platform interfaces follow the project definition

Acceptance and delivery boundaries

Suggested acceptance dimensions

  • Verify DI, DO, AI, AO and communication data item by item against the point list, checking data types and units
  • Verify local interlocks, delays, resets and abnormal input handling against the control logic table
  • Simulate gateway network loss, controller restart and platform unreachability, and confirm local functions and remote status
  • Check status consistency and operation audit between the HMI, platform and controller

Limitations and exclusions

  • An integrated architecture does not mean one device performs every function; control, communication and display can still be separated by risk
  • Unverified I/O capacity, scan period, bus or certification figures must not be written as technical commitments
  • Remote platform operation cannot bypass on-site HMI permissions, hard protection or manual confirmation
  • Production operation must not begin before electrical drawings, control logic and safety approval are complete

Operational value

  • Reduces duplicate construction of field acquisition, logic and display systems
  • Makes the boundary between local control and remote O&M clearer
  • Lowers maintenance and troubleshooting effort through a unified point table and audit records

Selection guidance

  • Decide first whether the project genuinely needs local control; do not add unnecessary logic for a monitoring-only requirement
  • Select controllers and modules by I/O type, count, real-time behaviour and isolation requirements, not by series name alone
  • HMI size, interfaces and protection rating must be confirmed against the installation environment
  • Where safety interlocks are involved, assess the safety circuit independently and do not treat ordinary control capability as safety certification

Typical implementation patterns

  • Typical implementation pattern: a manufacturing site connects scattered sensors, device status and auxiliary actuators to a local control layer, CC100 or a matching controller executes the logic, CW uploads to the platform, the HMI supports on-site confirmation, and acceptance covers network-loss and control scenarios. This is an anonymized typical pattern and does not represent specific customer production line delivery.

Before retrofit → With the solution

Before retrofit

  • Field acquisition, PLC logic, I/O interlocking, local display and remote O&M are spread across different systems
  • Point tables and device status are maintained twice, and faults are hard to attribute to acquisition, control or communication
  • Monitoring alarms are coupled too tightly with local control, lacking safety boundaries and operation audit

With the solution

  • Reduces duplicate construction of field acquisition, logic and display systems
  • Makes the boundary between local control and remote O&M clearer
  • Lowers maintenance and troubleshooting effort through a unified point table and audit records

How to evaluate the effect

01

Measurable signal

Field sensors, instruments, switch status and device signals enter the edge layer throug…

02

Data source

CW Edge Computing Gateway · CC100 PLC Local Controller

03

Review method

Verify DI, DO, AI, AO and communication data item by item against the point list, checking data types and units

04

Acceptance boundary

An integrated architecture does not mean one device performs every function; control, communication and display can still be separated by risk

Frequently asked questions

Does integrated mean one device performs every function?

Not necessarily. A controller, gateway, I/O and HMI can be used in layers within one architecture; the key is clear data and control boundaries.

Can CC100 handle all control tasks?

That cannot be inferred from the series name. I/O scale, scan capability, interfaces and suitable applications must be confirmed against the specific model and technical documentation.

Must the HMI be the same brand as the controller?

Not required, but communication protocol, data dictionary and commissioning conditions must be confirmed, and mixed products must be compatibility tested.

Does platform network loss affect the local HMI?

Local HMI and controller can usually continue on the local network, depending on the network architecture and login method. Confirm local standalone operation capability during selection.

Should I/O modules be fully equipped at once?

Configure for the actual first-phase requirement with reasonable expansion margin. Over-configuration adds cost and maintenance scope, while insufficient margin limits later expansion.

Request a matched product combination and project review

Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.