ESX Smart Edge Computing Gateway
Acquires site device status and provides unified data to the platform; specific access scale is confirmed by model
A distribution topology display rests on confirmed engineering documents, device codes and point mapping, not on putting up a video wall. Once the platform links cabinets, circuits, devices and live status, anomalies can be located on the topology. The capability can be presented as a lightweight digital twin or an operating topology, but it is not equivalent to electrical simulation, protection settings or equipment life analysis, and document versions and site changes must be maintained continuously.
The solution improves spatial and logical location in distribution systems. The focus is to establish stable relations between engineering document objects, device assets, acquisition points and alarm status, then provide a topology and fault location entry point viewable by permission.
Acquires site device status and provides unified data to the platform; specific access scale is confirmed by model
Provides a simplified topology and status view on site; specific graphic capability and interfaces are confirmed by model
Maintains device, point, graphic element and alarm relationships and provides topology display and location entry points
Connects field device and point data to the platform as the live data source for topology status
Local deployment option for projects where distribution documents and data should not leave the site; architecture is confirmed per project
Field instruments, breakers and gateways provide circuit status, measured values and communication status
Edge devices perform data acquisition, quality checks and necessary buffering
FEXLINK binds device codes, topology nodes, raw points and alarms into a queryable relationship
O&M staff view device status, alarms and history from a topology node and locate the corresponding cabinet and circuit
Topology Node Coverage Rate
The platform calculates the ratio of modeled and point-bound topology nodes to design nodes
By distribution room/cabinet/circuit hierarchy separately
Topology display does not perform short-circuit calculation, protection coordination or electrical simulation
Based on device IDs and point mapping
No. A digital twin may include 3D, but its core is the relationship between physical objects and data. In distribution O&M, stable links between devices, topology, points and status are more practical.
Not necessarily. Documents support modeling, but object recognition, device codes and point mapping are still required, and document formats and conventions affect how much can be converted automatically.
Set the refresh frequency according to the business need. Switch status, alarms and measured values can run at different periods, and a very fast global refresh adds network and platform load.
Only to nodes that are modeled and have valid status or alarms. Uncovered devices, incorrect points or inaccurate site documents affect the location result.
Update the topology through a version publishing process and record the editor and effective time. Overwriting the old version makes historical alarms hard to reconstruct.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.