Direct Answer
Peak/flat/valley/sharp-tariff rates differ severalfold — how should a company read and use a TOU tariff table? The time-of-use tariff divides a day into sharp, peak, flat and valley periods — the valley rate is the lowest and the sharp rate the highest, with the difference up to several times — read the table with the local periods and the price difference, arrange the shiftable load into the valley periods as far as possible, and watch the demand risk in the sharp periods.
A scenario: A company cannot understand the TOU tariff table — it does not know which periods to produce in and which to avoid — equipment runs when it should stop and stops when it should run — it overpays the electricity bill for nothing. The logic is that the TOU tariff is not "one price for all" — different periods in a day differ severalfold — putting the load into the low-price periods naturally lowers the bill — reading the table is the first step and production scheduling the second.
1. The Definition of the Sharp/Peak/Flat/Valley Periods and the Scale of the Price Difference
The sharp period — the highest price: the most tense period of a day, usually the shortest; The peak period — the second-highest price: the demand-peak period, which shiftable load should avoid as far as possible; The flat period — the middle price: the normal period, billed at the regular rate; The valley period — the lowest price: the demand-valley period, which shiftable load should be arranged into as far as possible.
In one sentence: sharp > peak > flat > valley — the valley is the lowest and the sharp the highest, with the difference up to several times.
A reference for the typical price-difference scale — the valley rate is about one-third to one-half of the peak rate: varying by region; the sharp rate is about 3-4 times the valley rate: subject to the local catalog; the flat rate is in the middle: between the peak and the valley — the scale is a reference, and the catalog is the actual basis.
An example: A local TOU tariff: sharp 1.45 yuan, peak 1.15 yuan, flat 0.75 yuan and valley 0.35 yuan — the valley is about a quarter of the sharp. The logic is that the price difference is the "lever" of the TOU tariff — the same 1000 kWh costs 350 yuan in the valley and 1,450 yuan in the sharp — a difference of 1,100 yuan — production scheduling earns this price difference.
2. The Period Division May Differ by Season
The seasonal difference — the winter and summer periods differ: the summer sharp peak comes when the air-conditioning load is high, and the winter one may come when the heating load is high; The period adjustment — the TOU table updates by season: the sharp period may move with the season; The holiday difference — the periods may adjust on holidays: some regions execute special periods on holidays; The local basis — the period division depends on the local catalog: different regions and seasons have different periods.
In one sentence: the TOU table adjusts by season and holiday — follow the latest local catalog and do not use an old table for a year.
The common patterns of the period division — the sharp periods of summer and winter differ: dominated by the air-conditioning/heating load; some regions differ between weekdays and weekends: the load structure differs; holidays may run the whole day at the flat or valley rate: the production structure changes — the patterns differ and the local catalog prevails.
An example: In one region the summer sharp period is 19-21 and the winter one 17-19 — the same company avoids different periods in winter and summer. The logic is that the TOU periods are "dynamic" — the air-conditioning load dominates summer and the heating load winter — the periods follow the load — schedule by the current season's table, not by the old periods.
3. How to Arrange the Production Periods by the Local Tariff Table
Step one, get the local TOU table — the latest catalog price: confirm the sharp/peak/flat/valley periods and prices; Step two, mark the shiftable load — the movable production steps: which equipment can avoid the peak periods; Step three, arrange into the valley — move the shiftable load into the valley periods: move what can move to the low-demand periods; Step four, keep the critical production — keep the non-shiftable part: continuous processes and rigid loads run as needed.
In one sentence: get the local table, mark the shiftable load, arrange into the valley and keep the rigid production — the four steps give the optimal periods.
The identifying features of the shiftable load — pausable: the step can be interrupted and resumed; reorderable: the step order can be adjusted; buffered: with a material/storage buffer; power-hungry: the shifting benefit is obvious — the four features identify the movable load.
An example: A company moves the drying step from the peak to the valley period — the monthly bill falls 8% — the same equipment, only the period changes. The logic is that production scheduling does not change the energy use but the period — the period changes, the unit price changes and the bill changes — the more shiftable load, the bigger the scheduling space.
4. The Trade-off between Valley-Period Production and the Demand Risk
The benefit of valley-period production — a low price: the same energy is cheaper; The risk of valley-period production — concentrated demand: many devices start together in the valley and raise the peak; The consequence of the risk — exceeding the demand: the monthly maximum demand is raised and the basic charge increases; The principle of the trade-off — price vs demand: the money saved in the valley must cover the increase of the demand charge.
In one sentence: valley production saves the price, but a concentrated start raises the demand — the saved money must cover the increase of the demand charge.
The calculation method of the trade-off — the electricity saved in the valley: the valley energy times the price difference; the demand increase: the demand increment times the demand price; the net benefit = the price saving minus the demand increase — calculate the net benefit, then decide how much to arrange into the valley.
An example: A company arranges all equipment into the valley — the price saves 20,000 yuan — but the demand rises from 1000 kW to 1300 kW — at a demand price of 32 yuan, the basic charge increases 9,600 yuan — a net saving of about 10,000 yuan. The logic is that valley scheduling is not "the more the better" — a concentrated equipment start raises the demand — stagger the start and spread it over multiple periods — calculate the price and the demand together to be clear.
5. Tracking the Seasonal Adjustment and the Policy Price Change
The seasonal adjustment — change the table when the season changes: the periods follow the season and the scheduling follows; The policy change — the price adjustment: the catalog price may adjust and the cost basis follows; The tracking mechanism — check at fixed points: verify the latest table before the season change and after a price adjustment; The tracking tool — automatic platform update: maintain the TOU table in the platform and the scheduling suggestion follows.
In one sentence: change the table at the season change and follow the price adjustment — check at fixed points and let the platform update automatically.
The landing actions of the tracking — set the check points: one week before the season change and after the price-adjustment announcement; assign the responsible person: the energy administrator checks; update to the platform: maintain the TOU table in the energy supervision center — the three actions keep the tracking in place.
An example: A company maintains the TOU table in the platform — the platform updates the periods automatically at the season change — the scheduling suggestion adjusts automatically — the annual bill is 6% lower than manual scheduling. Another example: A company checks the TOU table every April and October — adjusts the scheduling before the summer table takes effect — the annual bill stays stable and controllable. The logic is that manual scheduling depends on people remembering the table and platform scheduling depends on the system following it — once the table changes, the suggestion changes — with the tracking mechanism built, the scheduling stays stable. And the TOU tariff is a "living table" — the season changes, the policy changes and the periods change — no tracking means a loss — maintain the table in the platform and the scheduling suggestion follows the periods automatically.
Back to the TIANYAN engine E-06 match — the TIANYAN E-06 (load prediction) predicts the future load curve in advance — identifies the shiftable window and anticipates the valley capacity — the enterprise arranges the movable load into the valley and avoids the sharp periods — and predicts the peak window and staggers in advance — avoiding the peak saves money and controlling the demand prevents the excess — scheduling moves from "guessing" to "calculating".
The TOU tariff divides a day into sharp, peak, flat and valley — the valley is the lowest and the sharp the highest, with a severalfold difference — read the table with the local periods and the price difference and update by season — the four scheduling steps: get the local table, mark the shiftable load, arrange into the valley and keep the rigid production — valley production must weigh the demand risk, because a concentrated start raises the peak — change the table at the season change and follow the price adjustment — the TIANYAN E-06 predicts the load curve and identifies the valley window — avoiding the peak saves money and controlling the demand prevents the excess — once the TOU tariff is readable, the bill falls.
Scope and Limitations
- The conclusions in this article are intended for LV distribution and electrical-safety sites. Criteria are compiled from public codes and FEXLINK product documentation, and product parameters follow the latest selection handbook and product knowledge base.
- Quantitative criteria (protection zone, discharge and residual voltage, earth resistance, thresholds and grading) hold under the preconditions stated in this article. Where the site voltage level, earthing arrangement, environmental category or load profile differs, the figures must be recalculated. Specific configurations involving Tianyan engine E-06(load forecast) should be verified against actual circuit parameters.
- Specific product models and parameters are subject to the latest selection handbook and product knowledge base; this article does not constitute selection or procurement advice.
- Standard numbers cited here refer to the currently effective editions; when a standard is revised, the related quantitative conclusions must be re-checked.
- Deployment and implementation for specific projects must be carried out by qualified engineers based on site survey and design drawings.
Frequently Asked Questions
Peak/Flat/Valley/Sharp-Tariff Rates Differ Severalfold
Peak/flat/valley/sharp-tariff rates differ severalfold — how should a company read and use a TOU tariff table