Handles local I/O acquisition or auxiliary control where conditions allow; interfaces and capacity are confirmed by specific model
Legacy equipment retrofits should first identify reusable electrical quantities, dry contacts, mechanical states and manual records, then choose split-core sensors, wireless nodes, CX or CW for acquisition. The goal is to add status visibility and remote O&M capability, not to rebuild the equipment or replace its original control system. Conductor size, cabinet space, power, isolation and communication routing must be verified on site, and deployment is usually phased, local and reversible.
The solution targets older sites that cannot stop production or do not want to replace an entire equipment set at once. The focus is low-intrusion acquisition, edge access, data modeling and post-retrofit maintainability, avoiding damage to existing protection and operation for the sake of data access.
Handles local I/O acquisition or auxiliary control where conditions allow; interfaces and capacity are confirmed by specific model
Connects sensors, instruments or acquisition nodes and performs protocol conversion, buffering and upload
Builds the legacy equipment register, measurement points, status, alarms and historical data views
Reuse existing instruments, dry contacts and measurable electrical quantities first, adding split-core or non-contact sensors only where necessary
CX or CW acquires field signals and performs necessary conversion and buffering without changing the equipment's original control core
FEXLINK organizes data by equipment register and point model into status, trends and alarms
O&M staff view legacy equipment status and maintenance records, and management assesses operation and retrofit results
Reuse existing instruments, dry contacts and measurable electrical quantities first, add…
CX Industrial Wristband (Edge Computing) · CW Edge Computing Gateway
Check equipment codes, acquisition points, sensor mounting, power and communication routing for each unit
A non-intrusive retrofit does not change the equipment's original mechanical, electrical or safety performance
Usually adding monitoring through external sensors, dry contacts or communication interfaces without changing the equipment structure and core control logic. The exact boundary still depends on site electrical and mechanical conditions.
Assess dry contacts, analog signals, current, temperature or other measurable signals. Without a usable signal, only external sensors or manual records can be added; internal device data cannot be obtained from nothing.
It depends on the sensor type and mounting location. Split-core or non-contact options may reduce the need to shut down, but electrical safety and work permits still apply, and no shutdown-free guarantee can be given.
Controlled outputs can be added only where the original control interface, actuators and safety conditions allow. Most non-intrusive schemes start with monitoring, and control requires separate design and risk assessment.
A correct design keeps existing protection and control unchanged. Any wiring, power tapping and output connection must pass an electrical review, and rollback must be verified at acceptance.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.