CW Edge Computing Gateway
Handles site device access and project-confirmed link management, buffering and upload; dual-link capability is confirmed by specific model
In a dual-link scheme, first confirm whether the two paths come from different bearers, have independent power and are supported by the device; then define primary/backup priority, heartbeat, switchover, switchback and buffering policy. CW handles the site link and data access, FEXLINK records link status and alarms, and private deployment changes the platform-side network boundary. Any high-availability claim must be accepted through real link-break tests; "supports dual links" cannot replace a site availability conclusion.
The solution targets sites that must not lose data upload because a single route fails. The focus is independence of the two paths, switchover policy, buffered backfill and O&M observability, not adding one more SIM card.
Handles site device access and project-confirmed link management, buffering and upload; dual-link capability is confirmed by specific model
Displays link status, data time, alarms and backfill results
Platform-side local deployment for projects needing an independent network boundary and a customer private network
Field instruments and devices connect to the edge gateway through project-confirmed interfaces
CW selects the link per primary/backup policy, continuously monitors link health and buffers key data during interruption
FEXLINK receives data and records link source, switchover, recovery and data gaps
O&M views link health, data continuity and site alarms, and business systems use quality-marked data
Field instruments and devices connect to the edge gateway through project-confirmed inte…
CW Edge Computing Gateway · FEXLINK IoT Platform
Check the physical path, carrier identity, power and routing configuration of both links to confirm fault domains
The two links may share power, carrier networks or upstream facilities and cannot automatically be treated as independent fault domains
Not necessarily. If both SIMs come from the same carrier, the same base station or the same power supply, they may still fail together. The actual fault domains must be analysed.
A delay and jitter check can be configured to avoid frequent switching caused by short fluctuations. The policy depends on site network quality.
A gateway with buffering can retain key data during a link interruption and backfill after recovery. Completeness depends on storage, point count and outage duration.
If a link identifier is configured on the gateway and platform, the source and receive time can be recorded. Verify the log fields and display during acceptance.
No. Set priority for critical data and reduce frequency or buffer ordinary data to save bandwidth and cost.
Share the application, circuit conditions and existing system interfaces so engineers can confirm selection and implementation boundaries.