Three-Phase DIN Rail Multifunction Meter with Temperature Measurement
Three-phase DIN rail multifunction meter combining full-wave electrical parameters with temperature monitoring, bidirectional energy metering and MODBUS-RTU in both float and integer formats.
Overview
Key Features
Rich parameter set
CT/PT ratios, zero blanking, backlight and cyclic display are programmable.
Strong communication
Six baud rates, up to 38400bps.
Flexible model choice
Basic and enhanced versions by I/O and analog output count.
Standard protocol compatibility
Fully MODBUS-RTU compliant, simplifying connection to host systems.
Dual data formats
Values provided in both float and integer formats.
Integrated temperature sensing
Three-phase electrical parameters and temperature monitoring in one meter.
Technical Data
| Wiring | Three-phase four-wire / three-phase three-wire |
| Measured quantities | U/I/P/Q/S/PF/F plus bidirectional active and reactive energy |
| Temperature measurement | Supported (model 1 includes temperature measurement) |
| Analog output | 0~4 channels (0-20mA / 4-20mA) |
| Digital I/O | Up to 12 DI channels, up to 6 DO channels |
| Communication interface | RS485 (asynchronous half-duplex) |
| Baud rate | 1200 ~ 38400bps (9600 default) |
| Protocol | MODBUS-RTU (function codes 01/02/03/04/05/06/0F/10H) |
| Address range | 1 ~ 247 (up to 32 meters per bus) |
| Parity | N81 / E81 / O81 (N81 default) |
| Data format | Float and integer (int/long) formats |
Models & Selection
| Parameter | ZSD-10003-R | ZSD-11113-R | ZSD-14463-R |
|---|---|---|---|
| Temperature measurement | Yes | Yes | Yes |
| Analog output | None | 1 channel | 4 channels |
| Digital input DI | None | 1 channel | 4 channels |
| Digital output DO | None | 1 channel | 6 channels |
| Communication | RS485 | RS485 | RS485 |
| Protocol | MODBUS-RTU | MODBUS-RTU | MODBUS-RTU |
| Typical application | Basic parameters + temperature | Limited I/O and analog output | Full-function version |
Model naming rule:ZSD-10003-R ZSD-11113-R ZSD-14463-R
Installation
FAQ
How do I choose between the three models?
ZSD-10003-R is the basic version with electrical parameters and temperature measurement; ZSD-11113-R adds 1 analog output and 1DI/1DO; ZSD-14463-R is the full version with 4 analog outputs and 4DI/6DO.
Which protocol and data formats are supported?
The meter uses MODBUS-RTU with function codes 01/02/03/04/05/06/0F/10H and outputs both float and integer formats. Baud rate is selectable from 1200 to 38400bps, 9600 by default.
How is temperature measurement connected?
On models with the temperature function, sensors are wired to terminals T1~T4. Model 1 in this range is supplied with temperature measurement, and temperature is shown and uploaded with the electrical parameters.
What wiring options and address range apply?
Both three-phase four-wire and three-phase three-wire connection are supported. Addresses run from 1 to 247, with a maximum of 32 meters on each RS485 bus.
What certification applies and how is pricing provided?
Certification is held through a CE / CMA / CNAS accredited laboratory. Price is quoted per model and I/O configuration; Request a quote with the model code and the number of analog outputs needed.