Three-Phase DIN Rail Multifunction Meter with Temperature Measurement
Smart Lightning Protection

Three-Phase DIN Rail Multifunction Meter with Temperature Measurement

Three-phase DIN rail multifunction meter combining full-wave electrical parameters with temperature monitoring, bidirectional energy metering and MODBUS-RTU in both float and integer formats.

Up to 38400
Baud rate
MODBUS-RTU
Protocol
Up to 6 channels
DO

Overview

Three-Phase DIN Rail Multifunction Meter with Temperature Measurement · Product
Electrical parameter monitoring in distribution boxes and metering cabinets
Industrial automation system integration
Building and campus power distribution monitoring

Key Features

Rich parameter set

CT/PT ratios, zero blanking, backlight and cyclic display are programmable.

Strong communication

Six baud rates, up to 38400bps.

Flexible model choice

Basic and enhanced versions by I/O and analog output count.

Standard protocol compatibility

Fully MODBUS-RTU compliant, simplifying connection to host systems.

Dual data formats

Values provided in both float and integer formats.

Integrated temperature sensing

Three-phase electrical parameters and temperature monitoring in one meter.

Technical Data

WiringThree-phase four-wire / three-phase three-wire
Measured quantitiesU/I/P/Q/S/PF/F plus bidirectional active and reactive energy
Temperature measurementSupported (model 1 includes temperature measurement)
Analog output0~4 channels (0-20mA / 4-20mA)
Digital I/OUp to 12 DI channels, up to 6 DO channels
Communication interfaceRS485 (asynchronous half-duplex)
Baud rate1200 ~ 38400bps (9600 default)
ProtocolMODBUS-RTU (function codes 01/02/03/04/05/06/0F/10H)
Address range1 ~ 247 (up to 32 meters per bus)
ParityN81 / E81 / O81 (N81 default)
Data formatFloat and integer (int/long) formats
Certification:CE / CMA / CNAS accredited laboratory | Price & Lead Time:Request a quote

Models & Selection

ParameterZSD-10003-RZSD-11113-RZSD-14463-R
Temperature measurementYesYesYes
Analog outputNone1 channel4 channels
Digital input DINone1 channel4 channels
Digital output DONone1 channel6 channels
CommunicationRS485RS485RS485
ProtocolMODBUS-RTUMODBUS-RTUMODBUS-RTU
Typical applicationBasic parameters + temperatureLimited I/O and analog outputFull-function version

Model naming rule:ZSD-10003-R ZSD-11113-R ZSD-14463-R

Installation

Dimensional drawing
Dimensions and mounting holes are listed in the technical data table; the mounting pitch follows the standard 35 mm DIN rail.
Terminal layout
Terminals: supply side L1/L2/L3, N, PE; communication and signal terminals are wired as marked on the device.

FAQ

How do I choose between the three models?

ZSD-10003-R is the basic version with electrical parameters and temperature measurement; ZSD-11113-R adds 1 analog output and 1DI/1DO; ZSD-14463-R is the full version with 4 analog outputs and 4DI/6DO.

Which protocol and data formats are supported?

The meter uses MODBUS-RTU with function codes 01/02/03/04/05/06/0F/10H and outputs both float and integer formats. Baud rate is selectable from 1200 to 38400bps, 9600 by default.

How is temperature measurement connected?

On models with the temperature function, sensors are wired to terminals T1~T4. Model 1 in this range is supplied with temperature measurement, and temperature is shown and uploaded with the electrical parameters.

What wiring options and address range apply?

Both three-phase four-wire and three-phase three-wire connection are supported. Addresses run from 1 to 247, with a maximum of 32 meters on each RS485 bus.

What certification applies and how is pricing provided?

Certification is held through a CE / CMA / CNAS accredited laboratory. Price is quoted per model and I/O configuration; Request a quote with the model code and the number of analog outputs needed.