Insulation Resistance Online Tester
Online insulation resistance monitoring over 1~8 channels with a 0.1MΩ~20GΩ range, RS485 remote polling and Bluetooth near-field commissioning. Absorption ratio and polarisation index are calculated on the device.
Overview
Key Features
Multi-channel monitoring
1~8 channel cyclic testing covers several busbar sections on one instrument.
Wide range, high accuracy
0.1MΩ~20GΩ range with accuracy up to ±5%rdg.
Adjustable output voltage
50V~500V user-defined test voltage.
Three control methods
Front-panel keys, RS485 remote commands and Bluetooth near-field setup.
Insulation data analysis
Absorption ratio DAR and polarisation index PI calculated with the resistance reading.
Two mounting options
35mm DIN rail or screw fixing on site.
Technical Data
| Operating power supply | DC 12V ~ 24V (external supply, ≥1A) |
| Power consumption | Standby 0.8W, maximum 12W |
| Display | 0.96 inch OLED (21.7×10.9mm) |
| Output voltage | 500V / 50~500V configurable |
| Insulation resistance range | 0.1MΩ~10GΩ / 0.1MΩ~20GΩ |
| Measurement accuracy | 0.1MΩ~1GΩ: ±5%rdg±5dgt; 1~10GΩ: ±10%rdg±10dgt; 10~20GΩ: ±15%rdg±10dgt |
| Short-circuit current | 2mA MAX |
| Communication | RS485 (MODBUS) / Bluetooth (3580B model only) |
| Test channels | 1 ~ 8 (COM terminal shared) |
| Test duration | 20 s / 60 s / 1 min / 10 min |
| Mounting | 35mm DIN rail or screw fixing |
| Degree of protection | IP20 |
Models & Selection
| Parameter | WSR-18100-R | WSR-18211-R | WSR-18211-B |
|---|---|---|---|
| Output voltage | 500V | 50/100/250/500V configurable | 50/100/250/500V configurable |
| Insulation resistance range | 0.1MΩ~10GΩ | 0.1MΩ~20GΩ | 0.1MΩ~20GΩ |
| RS485 communication | Yes | Yes | Yes |
| Bluetooth communication | None | None | Yes |
| Absorption ratio / polarisation index | — | Supported | Supported |
Model naming rule:WSR-18100-R WSR-18211-R WSR-18211-B
Installation


FAQ
How many insulation channels can be monitored at once?
Between 1 and 8 channels can be wired to one tester, sharing a common COM terminal. The channels are polled in sequence on RS485 remote commands, so a single instrument covers several busbar sections.
What are the measurement range and accuracy?
The insulation resistance range is 0.1MΩ~20GΩ. Accuracy is ±5%rdg±5dgt from 0.1MΩ~1GΩ, ±10%rdg±10dgt from 1~10GΩ and ±15%rdg±10dgt from 10~20GΩ.
Can absorption ratio and polarisation index be calculated?
The 3580B model calculates DAR over 1 minute and PI over 10 minutes, while the 3580 model measures insulation resistance and absorption ratio only. Test duration can be set to 20s, 60s, 1 min or 10 min.
What are the supply and mounting requirements?
An external DC 12V~24V supply of at least 1A is required, with 0.8W standby and 12W maximum consumption. The unit mounts on a 35mm DIN rail or by screws and is rated IP20.
What certification applies and how is pricing provided?
Certification is held through a CE / CMA / CNAS accredited laboratory. Price is quoted per configuration and channel count; Request a quote with the model code and the number of test channels.