C65 Surge Protective Backup Protector
Smart Lightning Protection

C65 Surge Protective Backup Protector

Limits induced lightning surges and internal grid overvoltages; 35mm DIN rail mounting, 2P/4P options, covering T1/T2/T3 test classes.

≤50ns
Response time
100kA
Maximum discharge current
0.3s
Power-frequency disconnection

Overview

C65 Surge Protective Backup Protector · Product
Main and sub-distribution boards in buildings
Telecom base stations, equipment rooms and server racks
Power entry of factory workshops and automation equipment

Key Features

Low Residual Voltage

Voltage protection level down to 1.5kV with response time ≤50ns, clamping overvoltages quickly

Multiple Configurations

2P/4P and 275V/385V combinations, compatible with AC and DC systems

High Surge Capacity

Nominal discharge current 20kA, maximum 40kA, absorbing high-energy impulses

T2 Class Protection

Effectively discharges induced lightning surges and internal grid overvoltages

Fast Response

Completes energy discharge within ≤50ns, protecting downstream precision equipment

Compact Design

2P is 36mm wide and 4P is 72mm wide, saving distribution box space

Technical Data

Rated operating voltage230/400V AC
Operating frequency50/60Hz
Maximum continuous operating voltage Uc275V / 385V AC
Nominal discharge current In10 / 20 / 30 / 40kA
Maximum discharge current Imax20 / 40 / 60 / 80 / 100kA
Voltage protection level Up1.5kV (Uc=275V) / 1.8kV (Uc=385V)
Response time≤50ns
Power-frequency short-circuit operating current3A
Power-frequency disconnection time0.3s
Power-frequency current disconnection cycles1000 cycles
Poles1P / 2P / 3P / 4P
Maximum conductor cross-section6~25mm²
Ambient temperature-40℃ ~ +80℃
Dimensions87.5×81.5×18mm (single pole)
Remote signallingOrdered separately
MountingStandard 35mm DIN rail
Certification:CE / CMA / CNAS accredited laboratory | Price & Lead Time:Request a quote

Models & Selection

ParameterSCSCB15SCSCB80SCSCB60SCSCB40SCSCB20
Test classT1T2T2T3T3
Maximum impulse current Iimp15kA————
Maximum discharge current Imax (8/20μs)—80kA60kA40kA20kA
Suitable SPD≤15kA (10/350μs)≤80kA (8/20μs)≤60kA (8/20μs)≤40kA (8/20μs)≤20kA (8/20μs)
Power-frequency short-circuit breaking capacity ISC50kA50kA25kA25kA15kA

Model naming rule:SCSCB15 SCSCB80 SCSCB60 SCSCB40 SCSCB20

Installation

Dimensional drawing
Dimensional drawing - C65 Surge Protective Backup Protector
Terminal layout
Terminal layout - C65 Surge Protective Backup Protector

FAQ

Which models make up the C65 backup protector range?

The range covers five models, SCSCB15, SCSCB20, SCSCB40, SCSCB60 and SCSCB80, in T1 and T2/T3 test classes. Maximum discharge current runs from 20kA to 100kA, and SCSCB15 is the T1 variant with 15kA maximum impulse current.

What role does the backup protector play in an SPD circuit?

It is connected in series ahead of the SPD and provides power-frequency short-circuit breaking capacity of up to 50kA. Operating current is 3A and disconnection time is 0.3s, preventing fire when a degraded SPD short-circuits.

How does SCSCB15 differ from the other models?

SCSCB15 belongs to test class T1 with a maximum impulse current of 15kA (10/350μs), so it sits at the direct lightning strike entry. The other models are T2/T3 classes, matched to SPDs of 20kA to 80kA on the 8/20μs waveform.

What are the mounting and wiring requirements?

Mounting is on a standard 35mm DIN rail, with a single-pole outline of 87.5×81.5×18mm and maximum conductor cross-section of 6~25mm². The supply side is wired to L1/L2/L3, N and PE.

What is the operating temperature range and certification status?

Operating temperature ranges from -40℃ to +80℃ and the device withstands 1000 power-frequency current disconnections. Certification is CE / CMA / CNAS accredited laboratory, and price is Request a quote per project.