Integrated Surge Protective Backup Protector
Smart Lightning Protection

Integrated Surge Protective Backup Protector

SPD and backup protection combined in one housing to reduce wiring nodes; power-frequency short-circuit breaking capacity up to 50kA and maximum discharge current up to 100kA.

100kA
Maximum discharge current
50kA
Power-frequency disconnection
≤50ns
Response time

Overview

Integrated Surge Protective Backup Protector · Product
Distribution cabinet retrofit where space is limited
Incoming supply of data centres and telecom equipment rooms
Power entry of industrial production lines

Key Features

Integrated Construction

SPD and backup protection in one housing, reducing wiring nodes and failure points

Power-Frequency Protection

Power-frequency short-circuit breaking capacity up to 50kA prevents fire from degraded SPDs

Strong Surge Capacity

Maximum discharge current up to 100kA (8/20μs)

Fast Response

Completes energy discharge within ≤50ns

Smart Maintenance

Local failure indication plus optional remote signalling alarm

Wide Temperature Range

Operating ambient temperature from -40℃ to +80℃

Technical Data

Rated operating voltage230/400V AC
Operating frequency50/60Hz
Maximum continuous operating voltage Uc275V / 385V AC
Nominal discharge current InUp to 40kA
Maximum discharge current Imax20 / 40 / 60 / 80 / 100kA
Voltage protection level Up1.5kV (Uc=275V) / 1.8kV (Uc=385V)
Response time≤50ns
Power-frequency short-circuit breaking capacity15kA / 25kA / 50kA
Power-frequency short-circuit operating current3A
Power-frequency disconnection time0.3s
Power-frequency current disconnection cycles1000 cycles
Poles1P / 2P / 3P / 4P
Maximum conductor cross-section6~25mm²
Ambient temperature-40℃ ~ +80℃
Dimensions87.5×81.5×18mm (single pole)
MountingStandard 35mm DIN rail
Certification:CE / CMA / CNAS accredited laboratory | Price & Lead Time:Request a quote

Models & Selection

ParameterSCSCB15SCSCB80SCSCB60SCSCB40SCSCB20
Test classT1T2T2T3T3
Maximum impulse current Iimp15kA————
Maximum discharge current Imax (8/20μs)—80kA60kA40kA20kA
Configured SPD≤15kA (10/350μs)≤80kA (8/20μs)≤60kA (8/20μs)≤40kA (8/20μs)≤20kA (8/20μs)
Power-frequency short-circuit breaking capacity ISC50kA50kA25kA25kA15kA

Model naming rule:SCSCB15 SCSCB80 SCSCB60 SCSCB40 SCSCB20

Installation

Dimensional drawing
Dimensional drawing - Integrated Surge Protective Backup Protector
Terminal layout
Terminal layout - Integrated Surge Protective Backup Protector

FAQ

How does an integrated unit differ from a split backup protector?

An integrated unit combines the SPD and the backup protection in the same housing, reducing wiring nodes and panel space. A split arrangement instead connects a separate SPD in series with a separate backup protector.

How do the models map to test classes?

SCSCB15 is T1 with an impulse current of 15kA (10/350μs). SCSCB80, SCSCB60, SCSCB40 and SCSCB20 are T2/T3 classes with discharge currents of 80kA, 60kA, 40kA and 20kA on the 8/20μs waveform.

What is the power-frequency short-circuit breaking capacity?

Breaking capacity is offered in three levels of 15kA, 25kA and 50kA. Operating current is 3A and disconnection time is 0.3s, so the device clears power-frequency short-circuit current after SPD degradation.

What are the mounting and environmental conditions?

Mounting is on a standard 35mm rail, with a single-pole outline of 87.5×81.5×18mm and maximum conductor cross-section of 6~25mm². Operating temperature is -40℃ to +80℃.

How is the product certified and purchased?

Certification is CE / CMA / CNAS accredited laboratory. Price and lead time are quoted per project, and remote signalling is available as an option.