FL Lightning Peak Current Monitor (Outdoor)
Smart Lightning Protection

FL Lightning Peak Current Monitor (Outdoor)

Rogowski coil sensing of lightning current from 1kA~120kA, recording peak value and charge energy, with 100-record circular storage in an IP65 outdoor housing.

1~120kA
Peak range
100 records
Storage
IP65
Protection

Overview

FL Lightning Peak Current Monitor (Outdoor) · Product
Lightning current monitoring on substations and line towers
Direct strike monitoring at oil and gas tank farms
Lightning statistics for wind and PV plants

Key Features

Accurate strike recording

Peak value, polarity, time of occurrence and energy recorded together.

Peak and energy measurement

1kA~120kA peak current plus charge-based energy metering.

100-record circular storage

Storage of 100 records; the earliest entry is overwritten.

Local alarm indication

Threshold set locally, 20kA by default; the indicator turns red above it.

Multiple communication options

RS485, Zigbee, Ethernet or 4G.

Outdoor-rated enclosure

IP65 protection and -20℃~60℃ operating range for permanent outdoor use.

Technical Data

SensorRogowski coil (flexible split-core)
Peak range1kA ~ 120kA
Energy measurementCharge in coulombs
Storage100 records, circular
Alarm thresholdLocally settable, 20kA default
CommunicationRS485 / Zigbee / Ethernet / 4G
Power supplyDC12V / AC220V / solar / lithium battery
Degree of protectionIP65
Operating temperature-20℃ ~ 60℃
Operating humidity<95%
MountingOutdoor wall mount / pole mount
Certification:CE / CMA / CNAS accredited laboratory | Price & Lead Time:Request a quote

Models & Selection

ParameterFL-01212FL-01222
Signal acquisition range1kA~120kA1kA~120kA
FunctionPeakPeak + energy
Power supplyExternal DC12VExternal DC12V
MountingOutdoorOutdoor

Model naming rule:FL-01212 FL-01222

Installation

Dimensional drawing
Dimensional drawing - FL Lightning Peak Current Monitor (Outdoor)
Terminal layout
Terminals: supply side L1/L2/L3, N, PE; communication and signal terminals are wired as marked on the device.

FAQ

Which lightning current parameters are recorded?

Peak current, polarity, time of occurrence and energy measured as charge in coulombs are recorded. Model FL-01222 supports peak plus energy, while FL-01212 records peak values only.

What is the peak range and measurement accuracy?

The sensing range is 1kA~120kA with a measurement accuracy of ±5%. The same range applies to both the peak-only and the peak-plus-energy versions.

How is data stored and read back?

An internal circular buffer holds 100 records and overwrites the earliest one when full. Records are read over RS485, Zigbee, Ethernet or 4G, or forwarded to a cloud platform.

What are the outdoor installation conditions?

The enclosure is rated IP65 and operates from -20℃~60℃ at humidity below 95%. Installation can be wall mounted or pole mounted.

What certification applies and how is pricing provided?

Certification is held through a CE / CMA / CNAS accredited laboratory. Price is quoted per model and communication option; Request a quote with the model code and the interface required.